Instruction Manual

1
How to install
OR
Step 1.
Install bracket
Step 2.
Install camera to bracket
2
Connect Interface
The dome camera cable include
power, RS-485, video
out.
Video out interface
RS-485 interface is two cable
is 485 A/+
is 485 B/-
Purple color
Gray color
±Úʽ°²×°·½Ê½
The dome camera can be setup address baud rate
and protocol from PTZ Controller.
How to setup address
3
P 27X02
20 02
INITIAL...
PROTOCOL:PELCO-D
ADDRESS:001
BAUDRATE:9600BPS
INPUT PELCO COMMAND:
(IRIS-OPEN)-----OSD MENU
(IRIS-CLOSE)--- AUTO FOCUS
(GOTO PRESET 95) – OSD MENU
MAIN MENU
CAMERA SETUP
FOCUS SETUP
PAN TILT SETUP
PATTERN SETUP
PROTOCOL SETUP
RESET MENU SETUP
EXIT MENU
PAN TILT SETUP
PROTOCOL: PEL CO-D
ADDRESS: 001
BAUDRATE: 9600BPS
RETURN
EXIT MENU
(1)After Initial starting,the OSD will display 485 baud rate,
address,protocol,as following picture shown:
DVR or PTZ controller, the 485 Option sets up the same
as the PTZ camera,so you can make it work.
(2)Change the PTZ camera's 485 communication settings:
1)Press ''IRIS open'',and enter into OSD menu as following
picture shown
2)Enter in the submenu of PROTOCOL SETUP to setup
PROTOCOL,ADDRESS and BAUDRATE
MAIN MENU
CAMERA SETUP
FOCUS SET UP
PAN TILT SETUP
PATTERN SETUP
PROTOCOL SETUP
RESET MENU SETUP
EXIT MENU
FOCUS SETUP
FOCUS TYP E AUTO
AF AFTER MOVE ON
PRESET LOAD ZOOM ON
DISPLAY ZOOM TIMES OFF
RETURN
EXIT MENU
4
Pan Tilt Zoom Dome Camera OSD Manual
MAIN MENU
1.FOC US SETU P
1-1 FOCUS TYPE
AUTO: AUTO FOCUS
MANUAL: MANUAL FOCUS
1-2 AF AFTER MOVE ON/OFF
Auto Focus Setup After AF Move
1-3 PRESET LOAD ZOOM ON/OFF
Loaded ZOOM position when adjusting Preset
1-4 DISPLAY ZOOM TIMES
ON: Display ZOOM Times
OFF:Turn off Display of ZOOM Times
1-5 RETURN
Return to the previous menu
1-6 EXIT MENU
Exit Menu
MAIN MENU
CAMERA SETUP
FOCUS SETUP
PAN TILT SET UP
PATTERN SETUP
PROTOCOL SETUP
RESET MENU SETUP
EXIT MENU
PAN TILT SET UP
TILT LI MIT SET SET
TILT LIMIT RESET SET
PAN TILT LIMIT SPEED 063
ZOOM LIMIT SPEED 063
RETURN
EXIT MENU
2.PAN T ILT SET UP
2-1 TILT LIMIT SET
PTZ Upward angle limit setting:
In order to obtain a larger viewing angle range,
the machine factory set upward angle.
If you care about the camera in the ceiling spaces see the shell,
the user can set the upper limit position.
Turnning PTZ to the position you want to set,
Enter OSD and press IRIS-OPEN will set this position to Upper limit
2-2 TILT LIMIT RESET
Choose this menu and press IRIS-OPEN key will clear Tilt limit Setup
2-3 PAN TILT LINIT SPEED
PTZ speed Settign,63 is the fastest
2-4 ZOOM LIMIT SPEED
The ZOOM pulled speed Setup, 63 is the fastest
MAIN MENU
CAMERA SETUP
FOCUS SETUP
PAN TILT SETUP
PATTERN SE TUP
PROTOCOL SETUP
RESET MENU SETUP
EXIT MENU
PATTERN TOUR STOP
PATTERN POINT NUM 000
PATTERN DWELL TIME 010
RETURN
EXIT MENU
3.PAT TERN SE TUP
3-1 PATTERN TOUR
STOP:Stop PATTERN
START: Start PATTERN
3-2 PATTERN POINT NUM
The number of cruise point setting, if set 5,
then PATTERN between preset 1-5.
3-3 PATTERN DWELL TIME
PATTERN DWELL TIME Setup
.
MAIN MENU
CAMERA SETUP
FOCUS SETUP
PAN TILT SETUP
PATTERN SETUP
PROTOCOL SETUP
RESET MENU SETUP
EXIT MENU
PAN TILT SETUP
PROTOCOL: PEL CO-D
ADDRESS: 001
BAUDRATE: 9600BPS
RETURN
EXIT MENU
PROTOCOL: PEL CO-D
ADDRESS: 001
BAUDRATE: 9600BPS
RETURN
EXIT MENU
PAN TILT SETUP
PROTOCOL: PELCO-D
ADDRESS: 001
BAUDRATE: 9600BPS
RANDOM A DDRESS
EXIT MENU
PAN TILT SETUP
PROTOCOL: PELCO-D
ADDRESS: 026
BAUDRATE: 9600BPS
RANDOM A DDRESS
EXIT MENU
N 12X07
00 07
03 INITIAL...
PROTOCOL: PELCO-D
ADDRESS: 001
BAUDRATE: 9600BPS
INPUT PELCO COMMAND:
(IRIS--OPEN) ----- OSD MENU
(IRIS--CLOSE) ----AUTO FOCUS
(GOTO PRESET 95) – OSD MENU
4.PRO TOCOL S ETUP
RS485 PROTOCOL Setup
After turn PTZ OSD will display 485 baud rate,
address, protocol, and other information, as shown below:
N: NTSC
12X: Lens Zoom
07: Software Version
The setup status of PTZ
DVR or controller 485 set the same as PTZ,
then you can PTZ control.
Change RS485 PROTOCOL Setup
Press IRIS-OPEN Key to Enter MAIN MENU
4-1 PROTOL: PELCO-D/P
PROTOCOL you can choose PELCO-D or PELCO-P
4-2 ADDRESS:
Address set: 1~255
4-3 BAUDRATE:
4-4 : Address 255
4 Baud rate choose: 1200BPS/2400BPS/4800BPS/9600BPS
(NO.06 above support this feature)
Using address255,You can control all the same protocols and baud
rate connected with the DVR 485 but the address is different
from the PTZ.
Using address 255 control
press IRIS-OPEN Enter OSD choose PAN TILT SETU Submenu,
RETURN will become RANDOM ADDRESS
DVR:PELCO-D 001 9600 DVR:PELCO-D 255 9600
When you are in RANDOM ADDRESS
press IRIS-OPEN key
Will create a random address,
such as the right address 026
Has this feature the user do not set address before install PTZ,
255 address after installation can also be used to control and select
RANDOM ADDRESS to creat random addresses,
in this way, multiple head connected with the DVR
and 485 will have a different address,
And then use the new address can be controlled separately.
MAIN MENU
CAMERA SETUP
FOCUS SETUP
PAN TILT SETUP
PATTERN SETUP
PROTOCOL SETUP
RESET MEN U SETUP
EXIT MENU
RESET MEN U SETUP SET
FACTORY DEFAULT SET SET
RETURN
EXIT MENU
5.RES ET MENU S ETUP
5-1 RESET MENU SETUP
Recovery PTZ menu settings to the factory default
5-2 FACTORY DEFAULT SET
Resets all parameters to the original factory settings

Summary of content (2 pages)