User's Manual

HV Series
Whole House Cooling Fans
Product Manual & Installation Guide
HVM.02
PLEASE LEAVE WITH HOMEOWNER
Serial Number _________ Date of Purchase __________Point of Purchase _________________
What the HV whole house cooling fans do
The HV is used to assist the natural cooling process in the house. When the
outside temperature drops below the inside temperature, the cooler outside air
can be used to cool the house. The HV will pull the cooler air from the outside,
through the house, up into the attic and push the hot air outside. The HV is a fan
product and will not cool the house below the outside air temperature or create
a noticeable breeze. The HV can be used any time, for as long as needed, to
cool or change the air in the house.
The best location for your HV
The HV should be located as central as possible to the area that you want to
cool. Above a central hallway or at the top of a stairwell provide the best airflow.
The fan can also be mounted vertically, exhausting through a knee wall into an
under-the-eaves attic space. Cooler outside air should be able to move through the window, the space that needs to be
cooled, and exhaust out through the fan into the attic. Warning: Not to be used over cooking appliances.
Before installing your HV: Read all instructions carefully
Some state and local electrical codes require fan products be installed by a licensed electrician. Check with your local
code officials before installation.
Make sure that you have adequate net free exhaust area out of your attic. A minimum of 2 square feet is required for
the HV1000 and 3-1/2 square feet for the HV1600. This can be accomplished with a combination of roof, ridge, soffit or
gable end vents or other attic exhaust points.
Make sure that there is enough clearance for the doors to open. Minimum requirement for the HV with R22 insulating
doors (HV1000 and HV1600-GR) is 11” and 12” for models with R38 insulating doors (HV1000-DB and HV1600-GDR).
Make sure that there aren’t any pipes, wires, rafters, or air conditioning or heating ducts running through the space
where the HV will be installed and that the doors will face an unoccupied area.
Unpacking your HV: When you have unpacked your HV carefully you will find the following:
Please note the serial number, date of purchase and the point of purchase on the top of this page for handy
reference. The serial number is located on a label affixed to the HV next to the junction/utility box.
©Tamarack Technologies, Inc.• 320 Main Street • Buzzards Bay, MA 02532
508-759-4660 • 800-222-5932 • Fax 508-759-6001 www.tamtech.com
HV1000 (silver faced insulation)
One (1) HV1000 Whole House Cooler
One (1) White Metal Grille w/(6) Screws
One (1) Package of Foam Gasket
One (1) Metal Electrical Box Cover w/(2) Screws
One (1) Wall Switch (SPST)
Four (4) #8x3/4 Screws
One (1) Grounding Screw (green)
HV1600 (gold faced insulation)
One (1) HV1600 Whole House Cooler
One (1) White Metal Grille w/(6) Screws
One (1) Package of Foam Gasket
Four (4) #8x3/4 Screws
One (1) Hand Held Remote Transmitter
HV1000
DO NOT
PULL ON,
CARRY BY
OR STRESS
THE DOORS

Summary of content (4 pages)