Instructions / Assembly

Page 7
Controller must be connected to fan
for unit to function, even if it is not
ultimately installed in a wall.
UseredCAT5ecable(50ft)toconnectDigital
Touch Controller to fan. NOTE: this cable is low
voltage, DO NOT run it parallel to to high-voltage
wiring; building codes generally require low-voltage
cables to be run through shielded conduit.
Use extreme caution when running this cable,
as even minor kinks can interrupt the signal
between the fan and controller.
We stronglyrecommendusingshtapeorasimilar
tool to assist you with this wiring.
Once the fan has been hung and the ductwork attached
thereto, slide the collared end of the duct over the collar on
the Powered AirLock’s transition. Use the provided square
drive bit and a cordless drill to fasten the two collars together
using the 6 provided collar screws.
Once the fan, fan cone, ductwork, and Powered AirLock
have been successfully connected. Finish by sealing this
seam with provided aluminum tape.
Connect actuators to fan using factory-installed,
grey MOLEX cable originating from the fan-
mounted electrical box
Support the ductwork under the bend using the provided
polypropylene webbing. To fasten the webbing to the attic
joists, fold over the end of the webbing and screw at least
two1½"orlongerwoodscrews(NOTprovided)through
both layers of webbing and into the joists.
Maintain ductwork’s 20" diameter throughout bend, keep the section of duct
immediately prior to the fan as straight as possible, and avoid contact with
anymetalxture,pipes,orconduits.
Fan installation
Tamarack HV5800M Whole House Fans Installation Manual, P/N HV5800M.1
©Tamarack Technologies, Inc., 2018. All Rights Reserved.