Instructions / Assembly

installation: wiring & controls
The standard control package included with this fan contains 1 wall-mounted Digital Touch Controller; 1 mounting
bracketforthecontroller;and50ft.ofredCAT5cable.
All wiring connections to the fan assembly are made at the fan-mounted electrical box. These include: a 10 ft, black,
factory-installed power cord; a 9 ft, grey, factory-installed MOLEX cord for connecting the Powered AirLock’s actua-
torstothefan;andthreeRJ45(“ethernet”)portsforconnectingthefanscontrolsandaccessories,labledasfollows:
First, locate the desired location for the Digital Touch Controller. Install the mounting bracket according to Figures
AC below.
THIS FAN WILL NOT OPERATE IF NOT CONNECTED TO THE PROVIDED
DIGITAL TOUCH CONTROLLER! If it is not desired to be installed in a wall, the
controllercanbeconnectedtothefanandkeptintheatticwiththeCAT5cable
kept spooled. Do not install the Digital Touch Controller in an external,
south-facing wall as this may expose its circuitry to excessive heat.
Use the mounting
bracket as a template to
mark the hole location.
Figure A
Cut out the hole. Place the mounting bracket
and secure its locking tabs
by tightening the silver
screws
Figure B Figure C Figure D
Connect the CAT5 cable.
Mount the faceplate to the
bracket with the provided
white faceplate screws
Page 8
ReturntotheatticandconnecttheredCAT5cabletotheRJ45portonthefanelectricalboxlabledW/S.Run
this cable from the electrical box to the location of the controller. NOTE: this is a low-voltage cable, DO NOT RUN
IT PARALLEL TO HIGH-VOLTAGE WIRING; building codes generally require low-voltage cable to be run through
shielded conduit.
ConnecttheCAT5cabletotheRJ45portonthebackoftheDigitalTouchController.Mountthecontroller’sface-
plate to the mounting bracket with the provided white faceplate screws, as shown above in Figure D.
Next, connect the MOLEX cord from the fan-mounted electical box to the MOLEX cord from the Powered AirLock’s
actuators. Finish by plugging the power cord into an outlet with uninterrupted 120-volt power.
installation: grillE
The cube-core grille is installed from within the living space after the fan, duct, and Powered AirLock have been
installedintheirnallocationwithintheattic.Frombeneaththeroughopening,rst,useahigh-qualitylatexcaulkto
seal all wood-to-wood and wood-to-metal seams within the space formed by the Powered AirLock and framing.
Next, mount the grille to the framing using the eight white wood screws provided. We strongly recommend pre-
drilling holes in the framing for these screws; be careful to prevent them from stripping.
Tamarack HV5800M Whole House Fans Installation Manual, P/N HV5800M.1