Instructions

tams elektronik
Booster B-4 English
8. Operation
Shunting the boundry between two booster sections
You should take care not to allow locomotives or trains to halt directly
on the boundary between two sections. This would lead to a connection
between the outputs and possible damaging of the two connected
boosters. The short circuit indication does not work under these
circumstances.
LED
The LED on the front lights or flashes indicating the operation modes or
problems that occur.
LED Meaning
red – constantly lighting Short circuit at the track output.
red – quickly flashing Switching off after exceeding the
max. temperature.
yellow – constantly lighting Booster in operation.
yellow – slowly flashing
(approx. 1 sec. cycle)
No signal from the control unit.
yellow – quickly flashing Programming has been started.
yellow – 2x flashing | break |
2x flashing
The booster has been switched off by
a points switching command.
red – 2x flashing | break |
2x blinken
The watchdog has been released and
the booster has been switched off in
consequence.
Page 23