tams elektronik
Booster B-6 tams elektronik
Function Input
value for
CV 7
Setting / Comment Display
Switching the
watchdog on and off
with DCC turnout
command
Default value:
–- / inactive
76
→ The RGB LEDs flash white.
Switch to switch turnouts on your digital
control. Set the desired turnout address
and enter a turnout setting command for
this address ("straight ahead" for "active"
or "branch" for "inactive"). The turnout
address and operating status are now set.
Autostart
Default value: active
80 Autostart active S1
81
Autostart inactive S0
Brightness of the RGB
LEDs
Default value: 3
90
1 = minimum brightness 1
91 … 97
2 … 8 2
98
9 = maximum brightness 9
Restart time after
5 short-circuits
Default value:
60 seconds
100 0 sec. 00
101 10 sec. 10
102 20 sec. 20
103 … 108 30 ... 80 sec. 30 … 80
109 90 sec. 90
Time until the short-
circuit switch-off
responds
(Short-circuit sensitivity)
Default value: 100 ms
110 20 ms 02
111 40 ms 04
112 60 ms 06
113 … 118 80 … 180 ms 08 … 18
119 200 ms 20
Max. duration of
inrush current
("Inrush time")
Default value:
500 ms
120 50 ms 05
121 100 ms 10
122 150 ms 15
123 … 128 200 … 450 ms 20 … 45
129 500 ms 50
28 | Settings / Configuration