6.1.2. Display and RGB-LEDs
Display Colour
of the RGB LEDs
Meaning
0.0 to 6.0
GO | present current consumption [A]
Booster GO Track voltage at booster output
is switched on.
Central
unit
GO
A valid input signal is present at
the booster input.
St.
STOP
Booster
STOP
Track voltage at booster output
is switched off.
Central
unit
GO
A valid input signal is present at
the booster input.
--
Booster GO
Track voltage at the booster
output is to be switched on.
Central
unit
STOP
There is no valid input signal at
the booster input.
--
Booster STOP
Track voltage at the booster
output is switched off.
Central
unit
STOP
There is no valid input signal at
the booster input.
--
A valid input signal is present (= control unit is set to
"GO"). However, the autostart function is inactive
(→ section 6.3.2 "Autostart function"), therefore the
track voltage at the booster output cannot be
switched on automatically. Switch on the track
voltage manually with the STOP-GO button.
Sh.
red-violet flashing: "Short Circuit" / short circuit
during operation
Eliminate the cause of the short circuit. If the short
circuit occurs repeatedly at the same point in the
layout, you may have to make changes to the layout
or increase the short circuit sensitivity (= time until
the short circuit cut-off responds).
Operation | 31