Manual
Table Of Contents
- 1. Getting started
- 2. Operation overview
- 3. Connections- 3.1. Safety instructions
- 3.2. Safe and correct soldering
- 3.3. Avoiding irreparable damage to the decoder!
- 3.4. Pin assignment LD-G-43 | Front side
- 3.5. Pin assignment LD-G-43 | Rear side
- 3.6. Using decoders with interface connectors
- 3.7. Use of the LD-G-43 in locomotives with AC motor
- 3.8. Mounting decoders without interface
- 3.9. Connecting LEDs to the function outputs
- 3.10. Connecting inductive loads
- 3.11. Connecting the switching inputs
- 3.12. Connecting a backup capacitor or buffer circuit
- 3.13. Connection of a SUSI module
- 3.14. Completion
 
- 4. Programming
- 5. Configuration variables and registers- 5.1. Overview configuration variables LD-G-43
- 5.2. Basic settings
- 5.3. Setting the address
- 5.4. Setting the motor control
- 5.5. Function mapping
- 5.6. Effects of the outputs
- 5.7. Settings for the switching inputs
- 5.8. RailCom and DCC-A settings
- 5.9. Settings for driving operation
- 5.10. Settings for analogue mode
- 5.11. Sensivity of the overload protection
- 5.12. Auxiliary functions
- 5.13. Information
 
- 6. Checklist for troubleshooting and error correction
- 7. Technical data
- 8. Warranty, EU conformity & WEEE
tams elektronik
tams elektronik LD-G-43
5.8. RailCom and DCC-A settings 
Name No. Input values
(Default)
Remarks and tips
Dynamic
RailCom 
information
10 0,1 (0) off 0
Reception statistics: 
The decoder keeps statistics on all 
DCC packets and reports the 
number of faulty packets / 
total number of packets in %. 1
In order to read out RailCom information, you have to make the following additional settings:
 CV 29 "Configuration data 1": RailCom on
 CV 28 "RailCom channels": at least channel 2 on
RailCom channels
Automatic 
registration 
according to RCN-
218 (DCC-A)
28 0 … 135 (131) no feedback with RailCom and no 
automatic registration 0
Channel 1 on  1
Channel 2 on  2
Recommendation: Always switch on channel 2 
when you have switched on channel 1.
Use of Dynamic channel 1  4
The setting only has an effect if 
channel 1 is switched on.
Automatic registration 
according to RCN-218 (DCC-A) 128
Notes on automatic registration according to RCN-218 (DCC-A):
The use of the DCC-A procedure is only possible with digital control units that support this registration 
procedure. To be able to use the automatic login via the DCC-A procedure, the following settings must be
made: 
 CV 29 "Configuration data 1": RailCom on
 CV 28 "RailCom channels": channel 1 and 2 on
 CV 28 "DCC-A": on
The activation of the Dynamic Channel 1 is optional. 
Notes on the use of Dynamic Channel 1: 
Some RailCom detectors can only receive address messages on channel 1. If these detectors are used, 
the application of Dynamic Channel 1 must not be activated.
Further information on RailCom and automatic registration according to RCN-218 (DCC-A) → section 2.9.
Configuration variables and registers | 55