1.3. Connecting cascaded modules LC-NG-01
You can connect (cascade) other LC-NG-01 modules to the outputs of the
LC-NG-01 (also in addition to light bulbs or LEDs) to switch them on and off
with a time delay together with a switch. Since each LC-NG-01 is connected
directly to the power supply, you do not have to take it into account when
determining the current for the output.
Using the same principle, you can also connect all other LC-NG modules
that are switched on and off via the switching input "IN".
Please note:
You must connect a 1N400x diode (x = 2..7) in the supply
line to each cascaded module (see connection example on
the next page). Note the polarity of the diode! Seen in the
forward direction, the diode is marked with a ring that is
offset towards the end.
If you do not connect the diode or connect it with the
wrong polarity, the switching input of the module will be
irreparably damaged during commissioning.