Stranded wires
You need stranded wires to connect the module. Recommended cross-
sections:
Connections to the power supply: > 0.14 mm²
Connection of push-buttons or switches: > 0.04 mm²
Connection of consumers: depending on the load
Switches or buttons
To trigger the switching input, you need the following, depending on
the version
a switch (e.g. item no. 84-51510-02) or
a push-button (e.g. item no. 84-5212x-05)
Further information → section 7.2
Connection of subordinate circuits
You must connect subordinate circuits via a relay and a protective diode
if the current of the circuit and the connected loads is higher than 200
mA or if galvanic isolation is required, i.e. the circuit is connected with
another type of current or to another circuit. In addition to the circuit,
you then need
a relay (e.g. monostable relay 1xUm / 3 A / 12 V, item no. 84-
61011-01),
a protection diode 1N400x, x = 2...7 (e.g. item no. 83-11200-10)