Anleitung | Manual | Mode d´emploi | Handleiding k LRA el ek tro ni Art. 70-02105 | 70-02106 Lastregel-Adapter für Wechselstrom-Motoren s Load control adapter for a.c.
© 07/2013 Tams Elektronik GmbH n Alle Rechte, insbesondere das Recht der Vervielfältigung und Verbreitung sowie der Übersetzung vorbehalten. Vervielfältigungen und Reproduktionen in jeglicher Form bedürfen der schriftlichen Genehmigung durch die Tams Elektronik GmbH. n ni n tro Technische Änderungen vorbehalten. n k n n n el ek All rights reserved.
LRA English Table of contents 1.Getting started ............................................................................17 2.Safety instructions........................................................................19 3.Safe and correct soldering.............................................................21 k 4.Operation overview.......................................................................23 5.Technical specifications.................................................................
English LRA Intended use The LRA is designed to be operated according to the instructions in this manual in model railroad locomotives with alternating current (a.c.) motor. Any other use is inappropriate and invalidates any guarantees. The LRA should not be assembled or mounted by children under the age of 14. Checking the package contents ni k Reading, understanding and following the instructions in this manual are mandatory for the user.
LRA English 2. Safety instructions Mechanical hazards Cut wires can have sharp ends and can cause serious injuries. Watch out for sharp edges when you pick up the PCB. Electrical hazards ni k Visibly damaged parts can cause unpredictable danger. Do not use damaged parts: recycle and replace them with new ones. el ek ta m Never perform wiring on a powered module. Assembling and mounting the kit should only be done in closed, clean, dry rooms. Beware of humidity.
English LRA Fire risk ni Thermal danger k Touching flammable material with a hot soldering iron can cause fire, which can result in injury or death through burns or suffocation. Connect your soldering iron or soldering station only when actually needed. Always keep the soldering iron away from inflammable materials. Use a suitable soldering iron stand. Never leave a hot soldering iron or station unattended.
LRA English In schools, training centres, clubs and workshops, assembly must be supervised by qualified personnel. In industrial institutions, health and safety regulations applying to electronic work must be adhered to. Caution: ni ! k 3. Safe and correct soldering ta m el ek Use a small soldering iron with max. 30 Watt or a regulated soldering iron. Only use electronic tin solder with flux. When soldering electronic circuits never use soldering-water or soldering grease.
English ta m s el ek tro ni Do not move the component for about 5 seconds after soldering. To make a good soldering joint you must use a clean and unoxidised soldering tip. Clean the soldering tip with a damp piece of cloth, a damp sponge or a piece of silicon cloth. Cut the wires after soldering directly above the soldering joint with a side cutter. After placing the parts, please double check for correct polarity. Check the PCB tracks for solder bridges and short circuits created by accident.
LRA English 4. Operation overview ni k Most locomotive decoders with load control are designed to control locomotives with direct current (d.c.) motor. There are only few locomotive decoders with load control available to control locomotives with alternating current (a.c.) motor. In order to drive a locomotive with a.c. motor in digital operation with load control, it is widespread to alter the motor (by replacing the field coil with a permanent magnet or exchanging it completely). Max.
English LRA 6. Assembling the kit You can skip this part if you have purchased a ready-built module. Preparation Put the sorted components in front of you on your workbench. ni k The separate electronic components have the following special features you should take into account in assembling: Electrolytic capacitors tro Electrolytic capacitors are often used to store energy. In contrast to ceramic capacitors they are polarized. The value is given on the package.
LRA English PCB LRA Component side k Assembly tro ni Proceed according to the order given in the list below. First solder the components on the solder side of the PCB and then cut the excess wires with the side cutter. Follow the instructions on soldering in section 3. el ek ! Caution: Several components have to be mounted according to their polarity. When soldering these components the wrong way round, they can be damaged when you connect the power.
English LRA Performing a visual check Perform a visual check after the assembly of the module and remove faults if necessary: 7. Connecting the LRA Preparation tro ni k Remove all loose parts, wire ends or drops of solder from the PCB. Remove all sharp wire ends. Check that solder contacts which are close to each other are not unintentionally connected to each other. Risk of short circuit! Check that all components are polarised correctly.
LRA English X1 | X2 Field coil wire 1 and wire 2 X3 Engine plate, field coil page X4 Engine plate, track page ni k X5 | X6 Motor output of the decoder Fixing el ek tro Advice: Possibly the locomotive´s driving direction does not match the direction set at the control unit after mounting the load control adapter. In this case you should exchange the connections X1 and X2 or X5 and X6 or program the decoder´s CVs that way, the driving direction is inverted.
English LRA 8. Check list for troubleshooting Parts are getting too hot and/or start to smoke. ! Disconnect the system from the mains immediately! The locomotive does not run. ni k Possible cause: one or more components are soldered incorrectly. à In case you have mounted the module from a kit, perform a visual check (à section 6.) and if necessary, remedy the faults. Otherwise send in the module for repair.
LRA English 9. Guarantee bond ni k For this product we issue voluntarily a guarantee of 2 years from the date of purchase by the first customer, but in maximum 3 years after the end of series production. The first customer is the consumer first purchasing the product from us, a dealer or another natural or juristic person reselling or mounting the product on the basis of selfemployment. The guarantee exists supplementary to the legal warranty of merchantability due to the consumer by the seller.
English LRA 10. EU declaration of conformity This product conforms with the EC-directives mentioned below and is therefore CE certified. ni Connect the transformer only to an approved mains socket installed by an authorised electrician. Make no changes to the original parts and accurately follow the instructions, connection diagrams and PCB layout included with this manual. Use only original spare parts for repairs. tro k 2004/108/EG on electromagnetic.
n n Informations et conseils: Actuele informatie en tips: n n tro http://www.tams-online.de n k Information and tips: ni Aktuelle Informationen und Tipps: n el ek n Garantie und Service: Warranty and service: Garantie et service: n s Garantie en service: n Fuhrberger Straße 4 DE-30625 Hannover fon: +49 (0)511 / 55 60 60 fax: +49 (0)511 / 55 61 61 e-mail: modellbahn@tams-online.