Instructions

tams elektronik
!
SV-2 English
Connections 1
Testing the switching amplifier
Connect temporally the sockets "GND" and "S1" with one another. The
points should switch now. If the points do not switch they are possibly
in the corresponding position. Switch the points by hand in the other
position and try to switch the points again. Then connect "GND" to
"S2". The points should switch again. Please note: You have to wait for
a moment (approx. 2 sec.) between the two switching operations in
order to get the capacitor reloaded.
Caution: If a component gets too hot, disconnect the module
and power supply from the mains immediately. Possible short circuit!
Check the assembly.
After a successful function test, disconnect the switching amplifier from
the power supply. Mount the module as desired in your model railroad
layout.
Page 15