Tandberg Data Maintenance
1209 Failed to fetch at
slot 09
Failed to eject
cartridge from
drive
1. Reboot the loader and retry the
operation.
2. Try to eject the cartridge from
the drive via the front panel menu.
3. Remove the drive FRU.
Connect power to drive and push
the drive’s eject button. If this fails,
remove cartridge by following the
drive’s emergency eject
procedure.
Defect drive or
robotics. Defect
cartridge.
2000 Drive not found Communication
error between
the loader and
the drive.
1. Reboot the loader and retry the
operation.
2. Remove back-panel cover plate
and check the SCSI cabling and
the ADI cabling.
SCSI and signal
cables, power
cables; defective
power supply;
defective drive.
2001 Drive hardware
fault detected.
The drive has
reported a
hardware fault.
Reboot the loader and retry the
operation. If the problem persists
replace the drive.
Defective drive
StorageLoader Installation and User Manual 63