StorageLibrary T40+ Series Installation and User Guide 101
13
13 Shipping or Transporting the
StorageLibrary
Re-inserting the Transport Locking Screws
If you need to move or ship the StorageLibrary you need to re-install the transport locking screws to
protect the robotics, and in order to keep the warranty. The screws secure the robotics to the chassis
and hold the robotics in a locked position during transportation. Use the instructions below to re-insert
the transport locking screws.
1. Locate the transport locking screws. They are marked with red plastic tabs (four M3x6 mm
screws).
2. From the FPI select Menu > Tools > Prepare to Ship and follow the instructions
displayed on the front panel interface. The robotics will automatically be moved to the lower front
position, and the magazines will pop out.
3. Remove all magazines.
4. Remove all cartridges from all the magazines.
5. Turn off the power switch on the back of the library.
6. Install the four transport locking screws. The screws secure the robotics to the front chassis. The
transport locking screws are wound into the robotics from the front of the library, two on each side
of the front bezel. See Figure 43.
7. If installed, remove the rack mount ears. If your library is a 24 slot version you need to remove the
two upper magazines by using the emergency eject tool. See Manual/Emergency Release of
Magazines. Re-insert all magazines.
8. If you need to ship the library, use the original packaging.