4.17.5 Backup Configurations
Backup FLASH stores a copy of each of the 16 user configurations when
you select Store Configs in Backup, you will be asked for the password
here.
If unsure of the user configurations or they become inadvertently modified,
the user configurations can be returned to a known state at any time by
the command Load Configs from Backup. This loads the 16 backup
configurations to the User FLASH, overwriting all user configurations that
are not write-protected. Individual configurations cannot be selected for
loading to the User FLASH.
The active (current) configuration is unaltered when you select Load
Configs from Backup.
4.17.6 Factory Default Configurations
There are 16 default configurations for both 525 and 625 line standards.
They are provided as examples and can be used as they are, if their
settings suit your needs. They are non-editable. The 16 default
configurations (525 or 625) can be loaded to the user FLASH at any time
by selecting Factory 525 (or 625) Defaults. This will overwrite all user
configurations that are not write-protected. Individual configurations
cannot be selected for loading to the User FLASH.
4.17.7 Configuration, Write-Protection
Any or all of the 16 user configurations can be write-protected by selecting
Write Protect Configs. A password is asked for. With the correct
password entered, the question Write protect Which Configs? appears.
Select which configurations to protect by pressing the associated softkey in
each case. This toggles the write-protect condition (On or Off) for each
individual configuration. The letter R when shown to the left of the config
number, indicates that the configuration is read-only (write-protected).
Any configuration that is write-protected will be displayed as read-only if
attempting to overwrite it.
4.17.8 Quick Configuration From the Summary Screen
The sixteen predefined user configurations are a quick and easy way to
configure the Encoder without having to enter individual parameters. The
Config Menu can be accessed directly from the summary screen (see
Section 4.4.2, Summary Screen) by pressing the Cfgs softkey. Press the
Load Active Config softkey (see Load Active Config Option on
page 4-122) and a list of configurations is shown (refer to Annex C,
Predefined User Configurations for details of individual configurations).
Select the required one by pressing the associated softkey. Nothing more
need be done. The Encoder is ready for use.