VSXNET SERIES High-performance subwoofers Operation Manual
Important Safety Instructions The lightning flash with arrowhead symbol within an equilateral triangle, is intended to alert the user to the presence of uninsulated "dangerous voltage " within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
Table of Contents Table of Contents 2. Introduction . ...................................................................................................................................................... 4 3. Unpacking .......................................................................................................................................................... 4 4. Preliminary Recommendation ........................................................................................................
2. Introduction 2. Introduction Designed, engineered and built in the United Kingdom, the VSXNET Series from Tannoy comprises of one band-pass and two direct-radiating subwoofers for demanding professional and commercial sound applications. Within the VSXNET Series, system designers can choose from a variety of sizes, power levels and low frequency characteristics to suit particular requirements. As indicated by their respective suffixes, the VSXNET 12.
. Interface Panel 5. Interface Panel Amplifier & DSP Panel • XLR FEMALE AUDIO INPUT — This is a lockable XLR line input socket for connection to the audio source. Fully Balanced. Pin 2 Hot (+), Pin 3 Cold (+), & Pin 1 Ground. • XLR MALE AUDIO LINK - This is a lockable XLR line output socket to link additional speakers. Fully Balanced. Pin 2 Hot (+), Pin 3 Cold (+), & Pin 1 Ground. • RJ45 NETWORK INPUT - For Control and monitoring functions over RS485. • RJ45 NETWORK LINK - For linking cabinets.
. Operation 6. Operation The range of products are fully integrated designs, all speaker management functions which include driver EQ, dynamic limiting, & crossover functions are carried out within the DSP, therefore the need for external amplification, active crossovers and limiters is not required. The only input from the user is crossover between full range cabinets & subwoofers, and room equalization (if necessary).
6. Operation 6.3 LED functions On switch on all of the LED’s will illuminate instantaneously. The first to go off is the green signal LED after about 1 second. The red limit LED will flash for 5-10 seconds, this is the unit performing a self diagnostic test. During this initial few seconds the audio is muted until the red LED stops flashing & the blue power LED is the only LED left illuminated. After the self diagnostic test is performed, the unit is ready to pass audio.
6. Operation 6.6 User DSP On/Off A user DSP On/Off switch is provided on the amp panel. This miniature switch is recessed and can be easily activated with a small screwdriver. The switch in the ‘OFF’ position will return the VNET loudspeaker back to the original factory settings, this basically means that any parameter edited in software (EQ, Crossover, Mute, Delay) can be defeated by activating this switch. This can be a very useful feature.
7. Network Connections 7. Network Connections Interconnection between the network computer and the speakers is very straight forward, using twisted pair cable and simple connectors. The RS485 interface operates on a shared bus so that a single computer can control any amplifier on the bus, and the computer may gather status information from any device on the bus. Each module contains a unique address so that no user input will be required to configure network nodes.
7. Network Connections Connections from the RS485 device to the speaker is as follows:- From RS485 Device RJ45 to VNET Network B+ Pin 1 A- Pin 2 GND Pin 5 Network connections between nodes are via rugged Neutrik ‘ethercon’ connectors; these are high quality and are compatible with standard RJ45 plugs. Node connections are made using standard RJ45 connectors and CAT5 cable. Long runs should be solid core, but standard is fine.
8. Software Installation 8. Software Installation The enclosed disc contains the Podware software package; a comprehensive editor, interface, & diagnostics tool for the VNET range of loudspeakers. Check the Tannoy website for any updates http://www.tannoypro.com The disk should ‘AUTORUN’, if not open the Podware folder & double click on the ‘Setup.exe’ icon. Your PC will need to have the Windows .NET Framework installed. If it does not, you will be directed to the necessary location to do so http://msdn.
8. Software Installation Hardware requirements:- Scenario Required Processor Recommended Processor Required RAM Recommended RAM Client (Windows Forms and Windows Services) Pentium 90 MHz* Pentium 90 MHz or faster 32 MB* 96 MB or higher Server Pentium 133 MHz* Pentium 133 MHz or faster 128 MB* 256 MB or higher *Or the minimum required by the operating system, whichever is higher. Installing the software from the CD 1. Exit all running programmes & insert the CD.
8. Software Installation 3. Confirm Installation. Click 4. If you accept the license agreement check ‘I Agree’. Then Click 5. The programme will begin installing 6. Installation Complete VSXNET Subwoofer Operation Manual rev 2.0.
8.
8. Software Installation PodWare communicates with VNET using a serial ‘COM’ port as a ‘network’ connection. When a network connection is open and actively connected to a compatible device, the system is said to be ‘On Line’.Whilst On-line, you can control the connected device in ‘real time’, and continuously receive status information from the device. When going online, the application will take a few seconds while it copies the settings in the device to the control panel.
8. Software Installation The control panel shows the model name (not editable), and firmware version for the device. The device properties panel also have an editable Configuration Name, and Loudspeaker name, the latter will appear in the tree menu after editing. Each panel will in addition have a complete set of controls relating to the adjustable parameters within the device (press the EQ/DELAY tab to access this section).
8. Software Installation VNET Control Panel The control panel for VNET allows VNET parameters to be viewed and adjusted. The panel is organised into a monitoring area (at the top left of the panel) where the status of VNET may be viewed, and a control area where all the controls to adjust parameters are located. Note that Parameter adjustments are automatically stored in the DSP section of each VNET - it is not possible to do temporary changes then store them separately.
8.
8. Software Installation Protection (factory optimised) Comprehensive protection features preserve the longevity of the amplifier by continuously monitoring several critical parameters, and reducing the gain, or muting the amplifier either temporarily or permanently depending on the nature and seriousness of the fault or misuse. The amplifier will recover and restart if at all possible, but will remain shutdown if a serious fault persists (such as a permanent short circuit on the output).
8. Software Installation 8.1 Updating Firmware Occasionally it may be necessary to update the devices firmware (with file extension .dfw); this may be due to added features or amendments to the VNET product. Check with your dealer/distributor or (www.tannoypro.com) for any applicable updates. Firmware can be updated over the network (no need to disconnect speakers from the network). A firmware update will be common to all VNET products (one file for all models).
8. Software Installation 8. At the bottom right hand side of the screen a blue bar will show the progress of the firmware update. 9. After the download is complete the following message appears. The DSP is updating at this point. Do not power down the unit or disconnect any network cable at this point. During the update a red bar will show the progress of the firmware update (bottom right of screen). 10. The device will then power cycle automatically. The loudspeaker is now ready for normal operation.
9. Equalisation 9. Equalisation VSXNET loudspeakers are designed to need no equalisation or correction to overcome system limitations. As a result, they will only need equalisation to compensate for difficult acoustic environments. Over equalisation can reduce system headroom, and introduce phase distortion resulting in greater problems than cures. If equalisation is required then it should be applied gently and smoothly.
10. Rigging and Safety Procedures 10. Rigging and Safety Procedures The Tannoy Professional hardware covered in this guide has been designed to offer quick, simple, cost effective and secure solutions for mounting specific Tannoy Professional loudspeakers. This hardware has been designed and manufactured with a high safety load factor for its specific role. To ensure the safest possible use of the hardware covered in this guide, it must be assembled in strict accordance with the instructions specified.
11. SECUR ET – VEB Eyebolt 11. SECUR ET – VEB Eyebolt Tannoy VSX subwoofers can be flown with high quality VEB M10 eyebolts with collar to BS4278:1984. The loudspeaker is equipped with internal angle plates, which also double as the flying points, and directly accept VEB M10 eyebolts. To install the VEB M10 eyebolts, remove the original M10 counter sunk screws from the locations where VEB M10 eyebolts are to be installed. Replace these counter sunk M10 screws with the VEB M10 eyebolts.
12. Dimensions VSXNET 15DR Fly Points 580.0 [22.83"] 494.0 [19.45"] 43.0 [1.69"] 580.0 [22.83"] 250.0 [9.84"] 422.0 [16.61"] 508.0 [20.00"] Fly Points VSXNET 18DR Fly Points 650.0 [25.59"] 43.0 [1.69"] 650.0 [25.59"] 564.0 [22.20"] 290.0 [11.42"] 588.0 [23.15"] Fly Points VSXNET Subwoofer Operation Manual rev 2.0.
13. Technical Specifications 13. Technical Specifications VSXNET 12.
13. Technical Specifications VSXNET 12.2BP VSXNET 15DR VSXNET 18DR Electronics Efficiency > 85% typically > 85% typically > 85% typically Damping Factor 120 ref 8 Ω 120 ref 8 Ω 120 ref 8 Ω Distortion < 0.05% @ 1 kHz -3 dB output (22 kHz handwidth) < 0.05% @ 1 kHz -3 dB output (22 kHz handwidth) < 0.05% @ 1 kHz -3 dB output (22 kHz handwidth) Input Impedance 5.6 k Ω unbalanced, 11.2 k Ω balanced 5.6 k Ω unbalanced, 11.2 k Ω balanced 5.6 k Ω unbalanced, 11.
14. Warranty 14. Warranty No maintenance of the VSXNET Series loudspeakers is necessary. As part of the MUSIC Group, Tannoy is committed to providing the highest quality products, service and user experience for our customers. One element of this commitment is our after sales support which now incorporates our extended Limited Warranty. In the event of any concern that is not addressed by this extended Limited Warranty we would ask you to contact us at care@music-group.
15. EU Declaration of Conformity 15. EU Declaration of Conformity (in accordance with ISO/IEC 1750-1) Document No: CE-VSX-1 We: Music Group Innovation SC Ltd Rosehall Industrial Estate, Coatbridge, ML5 4TF, United Kingdom In accordance with the following Directive(s): 2004/108/RC 2011/65/EU Electromagnetic Compatibility (EMC) Restriction of the use of certain hazardous substances (RoHS) Hereby declare that: Type of equipment Range name Models Professional loudspeakers VSXNET VSXNET 12.
16. Notes 16. Notes 30 VSXNET Subwoofer Operation Manual rev 2.0.
17. Notes 17. Notes VSXNET Subwoofer Operation Manual rev 2.0.
Revision Date : 25 November 15 tannoypro.com Tannoy operates a policy of continuous research and development. The introduction of new materials or manufacturing methods will always equal or exceed the published specifications. All specifications are subject to change without notice. Copyright (c) 2015 Music Group Innovation SC Ltd. All rights reserved.