User's Manual
page 12    Tantalus Systems Corp. 
LAN NETWORK STATUS LED (RED) 
Start-up/Power up  Solid RED 
Module is not programmed  Fast flashing RED 
Unassociated/Re-associating  Solid RED 
Valid association candidate found  Flashing RED 
Full network association confirmed  OFF 
LAN APPLICATION MESSAGE TRANSACTION LED (GREEN) 
Start-up/Power-up  OFF 
Message queued for transmission  Long flash GRN 
Valid message received (addressed to this device)  Short flash GRN 
LAN RF PACKET LED (AMBER) 
Start-up/Power-up  OFF 
RF packet transmitted  Long flash Amber 
RF packet received (LAN activity)  Short flash Amber 
Check the WAN LED on the mid cover to ensure full two-way communication with the NC-2200. 
If  Then 
The XR-3100 does not power up.  Remove the unit and replace it with another one. 
The XR-3100 powers up but does not 
appear to find a Tantalus channel. 
Remove the unit and replace it with another one. 
When back in the Meter shop, ensure that the 
Tantalus channel has been programmed in the scan 
list. 
The XR-3100 finds the Tantalus 
channel but does not appear to be 
addressed by the controller. 
Contact the NC-2200 Administrator to verify that the 
unit is being installed and the WAN Network ID has 
been registered in the database. If it has not been 
registered, ask that it be registered now.  
If you still can’t get a signal and you are only using the internal antenna, try installing an external 
antenna to the device to boost the signal strength. 