TASCAM CD-6010 35
7 – Other Functions
Checking the firmware version
To check the firmware version, use the
21 INFO
menu
item.
1 Select the
21 INFO
menu item.
2 Press the TRACK SKIP/DATA knob on the main unit or
the ENTER button on the remote control to show the
system firmware version on the display.
Version Build number
3 Press the TRACK SKIP/DATA knob on the main unit
or the ENTER button on the remote control again to
return to menu item selection.
Digital output format setting
You can set the format of the digital signal output from
the COAXIAL and XLR DIGITAL OUTPUTS. You can set
the output format using the
22 D-OUT
menu item. The
digital signal output format options are as follows (default
value:
AES
).
SPD S/PDIF (consumer)
AES AES/EBU with U bit (professional)
AE_ AES/EBU without U bit (professional)
NOTE
The digital output format setting is retained even when the
power is turned off.
Analog output attenuation
You can set the unit so that the analog output level
is attenuated by -4 dB. Set this appropriately for the
equipment connected to the outputs.
Use the
19 ATT
menu item to set whether or not -4dB
attenuation is used or not (default value:
OFF
).
NOTE
The attenuation setting is retained even when the power is
turned off.
Using the parallel connector
Using the CONTROL I/O PARALLEL connector, you can
use external parallel control to operate this unit.
Pin
No.
Function
(Pin 14 = H or Open)
Function
(Pin 14 = L)
IN/
OUT
1 GND GND -
2 PLAY FLASH 1 In
3 STOP FLASH 2 In
4 INDEX/DIR SEARCH FWD FLASH 3 In
5
TRACK SKIP FWD [¯]
FLASH 4 In
6
TRACK SKIP REV [Â]
FLASH 5 In
7 INDEX/DIR SEARCH REV STOP/LOAD In
8 FADER START/STOP (Reserved) In
9 FLASH LOAD TALLY FLASH LOAD TALLY Out
10 PAUSE TALLY PAUSE TALLY Out
11 NO DISC TALLY (Reserved) Out
12 STOP TALLY STOP TALLY Out
13 PLAY TALLY PLAY TALLY Out
14 REMOTE SELECT* REMOTE SELECT* In
15 PAUSE FLASH 6 In
16 CALL FLASH 7 In
17
SEARCH FWD []
FLASH 8 In
18
SEARCH REV [Ô]
FLASH 9 In
19 (Reserved) FLASH 10 In
20 (Reserved) FLASH PAGE** In
21 EOM TRACK TALLY EOM TRACK TALLY Out
22 (Reserved) (Reserved, fixed high) Out
23
RELAY OUT
(EOM DISC TALLY)
(Reserved) Out
24 (Reserved) (Reserved, fixed low) Out
25 +5V* +5V* -
IN: external command reception (operates active low,
when ground 30 ms or longer)
OUT: transport status display signal by open drain
(20V maximum voltage, 35mA maximum current, 10Ω
impedance)
*When pin 14 (REMOTE SELECT) is high or open, the
functions in the left column are active and ordinary
parallel control can be used. When set to low, the
functions in the right column are active and they can be
used as flash start keys.
**When pin 14 (REMOTE SELECT) is low, the high/low
status of pin 20 (FLASH PAGE) determines the track
assignments as shown below.
***100mA maximum supplied current
#14 #20 Flash start tracks
Low High 1–10
Low Low 11–20
The following connection example shows playback
control by fader start/stop.
START
STOP
Pin 1
FADER START
Pin 8
GND
PA RALLEL