Setting the master word clock
You can set the source to use for word synchronization.
1. Press the MENU button to open the
MENU
screen.
2. Open the
SYSTEM
menu.
3. Select
CLOCK MASTER
.
4. Press the DATA dial to move the cursor right to select the
setting.
5. Turn the DATA dial to set the master word clock.
INT
(default value): Use the unit's internal clock
EXT
: Synchronize with the word clock input through the
WORD SYNC IN connector
44.1KFIX
: Regardless of the file sampling frequency,
digital audio is always output at 44.1k FS.
6. After completing the setting, press the HOME button to
return to the Home Screen.
NOTE
The master clock setting is retained even when the power is
turned OFF.
Depending on the combination of master clock and
playback file sampling frequency settings, the digital output
sampling frequency will differ. (See "Master clock and digital
output combinations" below.)
Mono mix setting
You can set the mono mix output for when the STEREO/MONO
button is used to set the output to mono. The setting state is
shown to the left of the level meters.
1. Press the MENU button to open the
MENU
screen.
2. Open the SYSTEM menu.
3. Select
MONO MIX
.
4. Press the DATA dial to move the cursor right to select the
setting.
5. Turn the DATA dial to set the mono mix.
6dB L+R 
(default
value)
The left and right channels of the stereo
audio track are each attenuated by –6 dB,
summed and then output.
3dB L+R
The left and right channels of the stereo
audio track are each attenuated by –3 dB,
summed and then output.
L Mono
The left channel of the stereo audio track is
output from both L and R outputs.
R Mono
The right channel of the stereo audio track
is output from both L and R outputs.
6. After completing the setting, press the HOME button to
return to the Home Screen.
NOTE
The mono mix setting is retained even when the power is turned
OFF.
Master clock and digital output combinations
Depending on the combination of the master clock setting and the playback file sampling frequency, the digital output sampling
frequency varies. This table shows the combinations.
Master
clock
Master clock
setting
Playback file
sampling frequency
SRC
(automatic)
Digital output
sampling frequency
Notes
Internal
INT
44.1 kHz OFF 44.1 kHz The whole system uses 44.1kHz internal clock
44.1kHz FIX
44.1 kHz OFF 44.1 kHz Digital output is always 44.1 kHz
44.1kHz FIX
48 kHz ON 44.1 kHz Digital output is always 44.1 kHz
INT
48 kHz OFF 48 kHz The whole system uses 48kHz internal clock
External
(44.1kHz)
EXT
44.1 kHz OFF 44.1 kHz The whole system uses 44.1kHz external clock
External
(48kHz)
EXT
44.1 kHz ON 48 kHz
While syncing to 48kHz external clock, the
system uses 44.1kHz internal clock
EXT
48 kHz OFF 48 kHz The whole system uses 48kHz external clock
NOTE
The sampling rate converter (SRC) function is turned ON and OFF automatically.
If the clock is interrupted when synchronized with a 48kHz external clock, the unit will switch to internal clock, the sampling rate