5 - Using the Settings Panel
Initializing the Settings Panel
Select this to reset all settings in the Settings Panel.
ATTENTION
Depending on the input signal level, sudden loud sounds
could be output unexpectedly. We recommend initializing
settings when no sound signals are being input from
instruments or playback devices.
NOTE
The items on the INFORMATION page will not be initialized.
1. In the menu bar, open the View menu, and click Initialize.
The following confirmation message will appear.
Windows version
2. Click the “OK button in the message window to reset the
Settings Panel settings to their default values.
The items reset are as follows.
Following items on MIXER page
i EQUALIZER area settings: all initialized
i COMPRESSOR area settings: all initialized
i REVERB area settings: all initialized
i φ (phase) buttons (all channels): off
i THRU buttons (all channels): off
i EQ buttons (all channels): off
i COMP buttons (all channels): off
i PRE/POST buttons: off
i AUX 1-4 knobs (all channels): -inf.
i SOLO buttons (all channels): off
i MUTE buttons (all channels): off
i Pan sliders (all channels): center (C)
i Channel faders (all channels): 0.0 dB
i LINK buttons (all channel pairs): off
i REVERB buttons: on
i REVER RETURN knob: -inf.
i AUX MASTER 1/REVERB knob: 0 dB
i AUX MASTER 2-4 knobs: 0 dB
i STEREO MASTER fader: -infinity
Following items on ROUTING page
i LINE OUT 1: MASTER L
i LINE OUT 2: MASTER R
i LINE OUT 3: AUX 1 (SERIES 208i only)
i LINE OUT 4: AUX 2 (SERIES 208i only)
i LINE OUT 5: AUX 3 (SERIES 208i only)
i LINE OUT 6: AUX 4 (SERIES 208i only)
i LINE OUT 7: COMPUTER 1 (SERIES 208i only)
i LINE OUT 8: COMPUTER 2 (SERIES 208i only)
Resetting the reverb settings
Select this to reset the settings in the REVERB section on the
MIXER page.
ATTENTION
After resetting, you cannot restore the previous settings.
1. In the menu bar, open the View menu, and click Initialize
Reverb.
The following confirmation message will appear.
Windows version
2. Click the “OK button in the message window to reset the
reverb settings to their default values.
The items reset and their default values are as follows.
Reverb
type
Reverb knobs
PRE DELAY REVERB TIME DIFFUSION
HALL 90 ms 2.7 s 20
ROOM 25 ms 1.4 s 60
LIVE 6 ms 2.6 s 50
STUDIO 60 ms 0.4 s 70
PLATE 42 ms 2.7 s 50
The reverb type will also be set to HALL (default value).