User manual

gpio.Relais
Technical data
Operating voltage via USB, VBUS: 4,5 Volt – 5,5 Volt
Maximal current draw: ca. 200mA*
*) all Relays active, all Inputs active
Input voltage/current of opto-decoupled inputs:
Parameter Min. Typ. Max. Unit
low/passive -5 0 2 Volt
low/passive - 0 2.5 mA
high/active 2.5 5 28 Volt
high/active 3 8 60 mA
Limitations of relay contacting:
Maximal continuous current 6A
Maximal switch-on current 15A
Nominal voltage 250 V AC
Maximal contact voltage 400 V AC
Maximal switching power AC1 1.500 VA
Maximal switching power AC15 250 VA
1-phasen motor load, AC3-usage (230V AC) 0,185 W
Maximal switched current DC1: 30/110/220V 3/0,35/0,2A
Minimal switching load 500mW (10V / 5mA)
Contact material AgCdO
Caution! When operating the relay contacts with voltages higher
than 42V (AC/DC) strongly obey not to touch the board's surface
on the bottom side. Pin voltages there can be health damaging.
Voltages larger than 100V (AC/DC) imply mortal danger!
Achtung! Wenn über die Relaiskontakte Spannungen von mehr
als 42V (AC/DC) geschaltet werden, muss streng darauf geachtet
werden, dass die Baugruppen-Unterseite ("Lötseite") nicht
berührt werden kann, da solche Spannungen bereits
gesundheitsgefährdend sein können.
Bei Spannungen über 100V (AC/DC) besteht Lebensgefahr!
11/12