Install Instructions

2Precautions/SafetyInstructions
RMM_00029_09 9 / 42 ANPR Mobile
Illuminatorriskgroupandhazarddistanceevaluation
F01710,F01845
IRilluminatorlens36°(wavelength860nm,±15nmspectralbandwidth@50%ofmaxintensity)
Hazard
Ultraviolet
hazard
200‐400nm
(Es/Euva)
Retinalblue
lighthazard
300‐400nm
(Lb)
Retinalblue
lightorthermal
hazard
400‐780nm
(Lr)
Cornea/lens
infraredhazard
780‐3000nm
(Eir)
Retinalthermal
hazard,weak
visualstimulus
780‐1400nm
(Lir)
Risk
Group
ExemptGroup ExemptGroup ExemptGroup ExemptGroup ExemptGroup
HD
HD=Hazarddistance
TheproductisinExemptGroup,nolabellingrequired.
F01696
IRilluminatorlens17°(wavelength860nm,±15nmspectralbandwidth@50%ofmaxintensity)
Hazard
Ultraviolet
hazard
200‐400nm
(Es/Euva)
Retinalbluelight
hazard
300‐400nm
(Lb)
Retinalbluelight
orthermal
hazard
400‐780nm
(Lr)
Cornea/lens
infraredhazard
780‐3000nm
(Eir)
Retinalthermal
hazard,weak
visualstimulus
780‐1400nm
(Lir)
Risk
Group
ExemptGroup ExemptGroup ExemptGroup RiskGroup1 ExemptGroup
HD 0.27m
HD=Hazarddistance
TheproductinexcessofExemptGrouplimitsoitislabelled:
Table3: IRilluminatorRiskGroup andHazardDistance
ForilluminatorexceedingExemptGrouplimitcamerashallbeinstalledasdetailedinthefigure
below,atdistanceL>HD,thereisnorisktothepublic.
Operatorormaintenancestaffworkinginfrontofthecamera,facingtheilluminator,atdistance
less
HDmustuseappropriateshieldingoreyeprotection,aswritteninthelabelling.