Safety data sheet

SHENZHEN GREPOW BATTERY CO.,LTD.
TEL+86 755 29045795 FAX +86 755 61558171
HTTP://www.grepow.com E-mail:fangchaojun@grepow.cn
Date
Jan 05,2018 Report No:GRP-MSDS-20180105001
ADDWUSHIGANGCHUANGYIROADTONGFUYUINDUSTRIALPARK,LONGHUA VILLAGE
BAOANDISTRICT,SHENZHENCHINA
碳酸甲乙酯
EMC
C
4
H
8
O
3
623-53-0 2.784%
碳酸二甲酯
DMC
C
3
H
6
O
3
616-38-6 7.425%
碳酸丙烯酯
PC
C
3
H
6
O
3
108-32-7 1.670%
碳酸亚乙烯酯
VC
C
3
H
2
O
3
872-36-6 0.185%
六氟磷酸锂
LiPF6 21324-40-3 2.785%
CMC Carboxymethylcellulose 9004-32-4
0.25-0.35%
Polypropylene (C3H6)n 9003-07-0
2.0-4.2%
Copper Cu 7440-50-8
10-20%
Aluminum AI 7429-90-5
5-10%
Nickel Ni 7440-02-0
0.2%
SBR (C8H8C4H6)x 9003-55-8
0.6-1.0%
Carbon Black
C 1333-86-4
1.0-1.8%
Weight of metallic lithium per cell: 24.5±1.5g . There is no metallic lithium in the lithium polymer battery.
Description of first aid measures
General information No special measures required.
After eye contact
Flush eyes with plenty of water for several minutes while holding eyelids open. Get medical attention if irritation persists.
After skin contact
Remove contaminated clothing and shoes. Immediately wash with water and soap and rinse
thoroughly. Wash clothing and shoes before reuse. If irritation occurs, get medical
attention.
After inhalation
Remove victim to fresh area. Administer artificial respiration if breathing is difficult. Seek medical
attention.
After swallowing
Do not induce vomiting. Get medical attention.
Information for doctor
Indication of any immediate medical attention and special treatment needed
No further relevant information available.
Flammability: Not available.
Extinguishing media
Suitable extinguishing agents
Section 4. First Aid Measures
Section 5. Fire Fighting Measure