Use and Care Manual

07-06-11
2071
Wood Flooring Adhesive
NOTE: Exotic species of flooring such as; Brazilian Cherry, Mahogany, and other exotic woods may behave differently
than standard domestic hardwoods commonly used in flooring installations. Contact W.F. Taylor for installation
recommendations. Not recommended for Teak.
INSTALLATION:
1. Follow wood flooring manufacturer’s guidelines for layout, design and any special precautions for installation.
2. Spread adhesive using recommended trowel (see trowel recommendation chart). Parquet floors can be installed
immediately after adhesive is spread. Working time is approximately 30 minutes when installing parquet under acceptable
temperature and humidity conditions. When installing engineered plank and solid wood greater than 7/16" (11.10 mm)
allow 10 minutes advance cure or “flash off” time. Working time is approximately 50-60 minutes under acceptable
temperature & humidity conditions. When installing thin-gauged solid wood and exotic species 7/16" (11.10 mm) and less,
allow 20 minutes advance cure or “flash off” time for optimum strength buildup before installing wood. Working time is
approximately 40 minutes under acceptable temperature & humidity conditions. Adhesive must transfer 100% to the wood
floor. If substrate is non-porous, a longer advance cure or “flash offtime may be necessary. NOTE: Thin-gauged solid
wood and exotic species are very sensitive to job site conditions. Wood flooring manufacturer’s and Taylor written pre-
installation instructions must be strictly followed or the Taylor warranty will be void.
3. Lay wood flooring into adhesive. Wood may slip and move so be sure to secure the initial row to limit movement and
hold patterns. Occasionally lift a piece of wood to assure adhesive is achieving 100% transfer. If proper transfer is not
achieved, remove dried adhesive and apply more using recommended trowel. The use of tape to temporarily hold the
edges together may be necessary until installation is complete.
4. When installing near a solid object or wall, leave ample room for expansion (see flooring manufacturer’s recommended
expansion guidelines). Installing wood too tight against a stationary object will not allow room for normal wood expansion,
which may cause a failure. When installation is complete, use wedges or some object to hold wood in place while
adhesive dries. Remove wedges after initial setting of adhesive (approximately 2 hours) to allow for normal expansion of
wood. Failure to remove wedges may cause the wood flooring to buckle and pop off the substrate.
5. Roll and cross roll floor with a 100-150 lb. (45.36-68.04 kg) roller at the end of the installation to ensure proper transfer
of adhesive.
6. When installing unfinished solid wood flooring, wait a minimum of 72 hours before sanding.
7. When installing over radiant heated subfloors, turn the heat off for 24 hours before, during and 24 hours after
installation. Failure to turn the heat off may result in shortened working time of the adhesive. Floor temperature must not
exceed 85°F (29°C).
8. Restrict light traffic for a minimum of 16 hours. Restrict heavy traffic for a minimum of 24 hours after installation is
complete. Freeze-thaw stable.
PHYSICAL PROPERTIES
Appearance: Tan, smooth, easy-to-spread mastic.
Working time: Approximately 60 minutes.
Shelf life: One year in unopened container at 70°F (21.10°C).
Other features: Waterproof when cured, non-flammable. Freeze/thaw stable to 10°F (-12.22°C). Made with anti-
microbial agents that will provide its dry film with protection from fungal growth. This protection is
determined using the ASTM G21 test method.
Clean Up: Remove wet adhesive with a damp cloth. If dried, clean-up with Taylor Touchdown #9 Adhesive
Remover/Stripper.
CAUTION
DO NOT take internally. If swallowed, DO NOT induce vomiting. Call a physician immediately. KEEP OUT OF REACH OF
CHILDREN.
WARRANTY INFORMATION
This product is manufactured according to exacting quality control standards and is warranted to be free from manufacturing defects.
Defective material called to our attention within one year of manufacture will be replaced. No guarantee, expressed or implied, is made
regarding the performance of this product since the manner and conditions of application are beyond our control. For complete warranty
information, call Technical Services at 800-868-4583; visit us on the web at www.wftaylor.com; or e-mail us at info@wftaylor.com.
W.F. TAYLOR CO., INC. * FONTANA, CA 800.397.4583 * DALTON, GA 800.868.4583