Section 9. Physical And Chemical Properties
Not Applicable
Section 10. Stability And Reactivity
(1) This product is stable under ordinary conditions of use and storage.
(2) Damaged batteries will react with water. Non-discharged batteries contain
elemental Lithium. This is water reactive. This reaction gives off heat and
hydrogen gas. A thermal reaction may occur.
(4) Hazardous decomposition products: Carbon Monoxide (CO), Hydrogen
Fluoride (HF)
Section 11. Toxicological Information
(1) Irritancy: The electrolytes contained in this battery can irritate eyes with any
contact. Prolonged contact with the skin or mucous membranes may cause
irritation.
(2) Sensitization: No information is available at this time.
(3) Carcinogenicity: No information is available at this time.
(4) Reproductive toxicity: No information is available at this time.
(5) Teratogenicity: This product contains a known teratogen as indicated in the
chemical information in section 2.
(6) Mutagenicity: No information is available at this time.
Section 12. Ecological Information
Not applicable to this material/product.
Section 13. Disposal Considerations
Batteries must be completely discharged prior to disposal and/ or the terminals
must be taped or capped to prevent short circuit. This product does not contain
any materials listed by the United Stated EPA as requiring specific waste
disposal requirements. When completely discharged, it is not considered
hazardous. Disposal of large quantities of lithium power cells may be subject to
Federal, State, or Local regulations. Consult your local, state and provincial
regulations regarding disposal of these batteries.
Section 14. Transport Information
Product is shipped as:
Ground (DOT) Air (IATA/ICAO) Water(IMDG)
Non Hazardous Non Hazardous Non Hazardous