Model H63 Important: To the Operator
Liquid Crystal Display
The Liquid Crystal Display (LCD) is located on the front
control panel. The LCD is used to show the current
mode of operation, and whether or not there is
sufficient mix.
LED Indicator -- MIX LOW
The “MIX LOW” indicator flashes to indicate that there
is a low supply of mix. The mix hopper should be filled
as soon as possible.
LED Indicator -- MIX OUT
The MIX OUT indicator flashes to indicate that the mix
hopper has an insufficient supply of mix to operate the
freezer. At this time, the freezer will go into the
STANDBY mode of operation. To return the freezer to
the AUTO mode, fill the hopper with mix and press the
AUTO key. The freezer will automatically begin
operation.
Consistency Control
The viscosity (thickness) of the shake is controlled by
a sensing device called the consistency control. The
consistency control knob is located to the lower right
of the control channel. To achieve a thicker shake, turn
the knob clockwise and counterclockwise to achieve a
thinner shake consistency.
Allow the refrigeration system to cycle on and off 2 or
3 times before an accurate consistency can be
evaluated.
Product Ready Light
The Product Ready Indicator Light illuminates when
the product is ready to serve.
Reset Mechanism
The reset button is located under the right side panel.
The reset mechanism protects the beater motor from
an overload condition. If an overload occurs, the reset
mechanism will trip. To properly reset the freezer,
press the reset button firmly and clear the tone per
instructions in “Clearing Fault Tones” on page 15.
If the reset mechanism trips again, contact your
authorized Taylor Distributor to resolve the problem.
Warning: Do not use metal objects to
press the reset button. Failure to comply may
result in severe personal injury or death.
Operating Screen Descriptions
When the machine is powered the system will initialize.
The screen will display “INITIALIZING”. There will be
four types of data the system will check: LANGUAGE,
SYSTEM DATA, CONFIG DATA, and LOCKOUT
DATA. During the INITIALIZING... LANGUAGE
screen, the alarm will be on. If the system data,
configuration data, or lockout history data has become
corrupt, the following screen will alert the operator that
the system settings may have been changed.
NVRAM FAULT
RESET TO DEFAULTS
PRESS SEL KEY