User's Manual
22
Model H63Operating Procedures
090130
Sanitizing
Step 1
Prepare a pail of an approved 100 PPM sanitizing solu-
tion (examples: 2--1/2 gal. [9.5 liters] of Kay--5R or
2 gal. [7.6 liters] of Stera--SheenR). USE WARM WA-
TER AND FOLLOW THE MANUF ACTURER’S
SPECIFICATIONS.
Step 2
Pour the sanitizing solution over all the parts in the
bottom of the mix hopper and allow it to flow into the
freezing cylinder.
Note: You have just sanitized the mix hopper and
parts; therefore, be sure your hands are sanitized
before going on in these instructions.
Step 3
While the solution is flowing into the freezing cylinder,
take particular care to brush clean the mix level
sensing probes, the mix hopper, mix inlet hole, inner
and outer air tubes, the outside of the agitator housing,
and the agitator. Brush the exposed sides of the
hopper.
Step 4
Place the power switch in the ON position.
Step 5
Press the WASH key and allow the sanitizing solution
in the freezing cylinder to agitate for five minutes.
Figure 17
Step 6
With a pail beneath the dispensing spout, open and
close the draw valve six times. Draw off the remaining
sanitizing solution.
Figure 18
Step 7
Once the sanitizer stops flowing from the dispensing
spout, close the draw valve and press the W ASH key,
cancelling the beater motor operation.
Note: Be sure your hands are clean and sanitized
before continuing these instructions.
Step 8
Lubricate the o--rings on the inner and outer air tubes.
Place the inner air tube inside the outer air tube and lay
in bottom of mix hopper .
Figure 19