OPERATOR'S MANUAL Model 8756 Single Stage Pump Soft Serve Freezer Original Operating Instructions 069071-M 11/15/10 (Original Publication) (Updated 8/14/14)
Complete this page for quick reference when service is required: Taylor Distributor: Address: Phone: Fax: E-mail: Service: Parts: Date of Installation: Information found on the data label: Model Number: Serial Number: Electrical Specs: Voltage Cycle Phase Maximum Fuse Size: A Minimum Wire Ampacity: A E 2010 Carrier Commercial Refrigeration, Inc.
Table of Contents Section 1 To the Installer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Installer Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Air Cooled Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table of Contents - Page 2 Closing Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Draining Product From the Freezing Cylinder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Rinsing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Section 1 To the Installer The following information has been included in the manual as safety and regulatory guidelines. For complete installation instructions, please see the Installation Checklist. Site Preparation Review the area where the unit will be installed before uncrating the unit. Make sure all possible hazards to the user or equipment have been addressed.
Each unit requires one power supply for each data label on the unit. Check the data label(s) on the freezer for branch circuit overcurrent protection or fuse, circuit ampacity, and other electrical specifications. Refer to the wiring diagram provided inside of the electrical box for proper power connections. Water Connections (Water Cooled Units Only) An adequate cold water supply must be provided with a hand shut-off valve. On the underside of the base pan, two 3/8” I.P.S.
S Supply cords used with this unit shall be oil-resistant, sheathed flexible cable not lighter than ordinary polychloroprene or other equivalent synthetic elastomer-sheathed cord (Code designation 60245 IEC 57) installed with the proper cord anchorage to relieve conductors from strain, including twisting, at the terminals and protect the insulation of the conductors from abrasion.
Section 2 To the Operator The unit you have purchased has been carefully engineered and manufactured to give you dependable operation. This unit, when properly operated and cared for, will produce a consistent quality product. Like all mechanical products, it will require cleaning and maintenance. A minimum amount of care and attention is necessary if the operating procedures outlined in this manual are followed closely. as unsorted municipal waste.
Section 3 Safety We, at Taylor Company, are concerned about the safety of the operator at all times when they are coming in contact with the unit and its parts. Taylor makes every effort to design and manufacture built-in safety features to protect both operators and service technicians. S S Installing and servicing refrigeration equipment can be hazardous due to system pressure and electrical components.
DO NOT use a water jet to clean or rinse the unit. Failure to follow these instructions may result in serious electrical shock. S DO NOT allow untrained personnel to operate this unit. S DO NOT operate the unit unless all service panels and access doors are restrained with screws. Access to the service area of the unit must be restricted to persons having knowledge and practical experience with the unit, in particular as far as safety and hygiene are concerned.
Notes: Model 8756 7 Safety
Section 4 Operator Parts Identification Figure 1 Operator Parts Identification 8 Model 8756
8756 Parts Identification ITEM DESCRIPTION PART NO. ITEM DESCRIPTION PART NO. 1 PANEL A.-FRONT X22879 16 COVER-MIX TANK 024590 2 STUD-NOSE CONE 068410 17 FUNNEL-MIX 036637 3 BOLT-CARRIAGE 012347 18 TRAY-DRIP 22-7/8 X 5-1/8 014533 4 PANEL A.
Beater Door Assembly Figure 2 ITEM DESCRIPTION PART NO. ITEM DESCRIPTION PART NO. 1 HANDLE A.-DRAW ADJ X55096 7 BEATER A.-3.4QT-1 PIN X46231 1a HANDLE-ADJUSTABLE 028804 8 SHAFT-BEATER 032564 1b SCREW-ADJUSTMENT 055092 9 SEAL-DRIVE SHAFT 032560 1c O-RING-1/4 OD X .070W 50 015872 10 BLADE-SCRAPER-PLASTIC 046235 1d NUT-5/16-24 FINISHED HEX 029639-BLK 11 CLIP-SCRAPER·BLADE-7.00·IN 046236 2 ROD A.-PIVOT-SHORT X22388 12 O-RING-5/16 OD X .070W 016272 3 O-RING-3/8 OD X .
Air/Mix Pump Assembly ITEM DESCRIPTION PART NO. 1 CAP-PUMP 021276-9 2 PIN-RETAINING 021276-8 *3 PUMP A.-SOFT SERVE COMPLETE X22345 3a CYLINDER A.-PUMP 022345-1 3b PIN-RETAINING 021276-8 3c PISTON 021276-2 3d RING-CHECK 2” OD x 1/2 020050 3e O-RING 2-1/8 OD x .139 W 020051 3f BODY A.-VALVE X22345-3 3g O-RING - 13/16 OD x .139 W 021278 3h ELBOW-INLET 90 DEGREE 022502-4 4 ORIFICE 023425-50 5 O-RING - 3/8 OD x .070 W 016137 6 LINE A.-FLARE 038299 7 LINE A.
Accessories Figure 4 ITEM DESCRIPTION PART NO. ITEM 1 BRUSH-MIX PUMP BODY 023316 7 2 BRUSH-PRESSURE SWITCH 027647 3 BRUSH SET-LVB 050103 4 BRUSH-FEED TUBE 021101 5 BRUSH-DOUBLE ENDED 013072 6 BRUSH-REAR BEARING 013071 DESCRIPTION PART NO. BRUSH-DRAW VALVE 013073 *8 SANITIZER-STERA SHEEN GREEN SEE NOTE 9 LUBRICANT-TAYLOR 4 OZ. 047518 10 KIT A.-TUNE UP X49463-2 11 PAIL-10 QT. 013163 *Note: A sample container of sanitizer is sent with the unit.
Section 5 Important: To the Operator Figure 5 ITEM 1 2 3 4 5 DESCRIPTION POWER SWITCH (TOGGLE) RESET SWITCH MIX REFRIGERATION CONTROL STANDBY KEY WASH KEY Model 8756 ITEM 6 7 8 9 13 DESCRIPTION AUTO KEY PUMP KEY MIX LOW INDICATOR MIX OUT INDICATOR Important: To the Operator
Symbol Definitions Reset Button To better communicate in the International arena, the words on many of our operator switches and buttons have symbols to indicate their functions. Your Taylor equipment is designed with these International symbols. The reset button is located in the decorative plate above the SOFTECH controls. The reset protects the beater motor from an overload condition. Should an overload occur, the reset mechanism will trip.
Wash Adjustable Draw Handle When the WASH key is pressed, the light comes on, indicating beater motor operation. The STANDBY or AUTO modes must be cancelled first to activate the WASH mode. This unit features an adjustable draw handle to provide the best portion control, giving a better, consistent quality to your product and controlling costs. The draw handle should be adjusted to provide a flow rate of 5 to 7-1/2 oz. of product by weight per 10 seconds.
Section 6 Operating Procedures The Model 8756 has two freezing cylinders. The size of each freezing cylinder is 3.4 quarts (3.2 liters). Mix is stored in the lower front refrigerated compartment and is pumped up to the freezing cylinder by an air/mix pump. Duplicate the following procedures, where they apply, for the second freezing cylinder. We begin our instructions at the point where we enter the store in the morning and find the parts laid out to air dry from the previous night's brush cleaning.
Step 2 Install the drive shaft through the rear shell bearing in the freezing cylinder and engage the hex end firmly into the gear box coupling. Be sure the drive shaft fits into the drive coupling without binding. Step 4 Holding the rear blade on the beater, slide it into the freezing cylinder half way. Install the front scraper blade over the front holding pin. Figure 10 Figure 8 Step 5 Install the beater shoes. Slide the beater assembly the rest of the way into the freezing cylinder.
Step 6 Place the large rubber gaskets in the grooves on the back side of the freezer door. Figure 14 Step 9 Insert the prime plugs into the holes at the top of the freezer door and push down. Figure 12 Step 7 Slide the white plastic front bearings over the baffle rods. Make certain that the flanged end of the bearing is resting against the freezer door. DO NOT lubricate the gaskets or the front bearings. Figure 15 Step 10 Insert the baffle rods through the beaters in the freezing cylinders.
Step 11 With the door seated on the freezer studs, install the short handscrews on the bottom and the long handscrews on the top. Tighten the handscrews equally in a criss-cross pattern until the door is snug. Step 13 Lubricate the inside of the freezer door spouts, top and bottom. Insert the draw valves from the bottom of the door until the slot in the draw valves comes into view. Figure 17 Figure 19 Step 12 Slide the two o-rings into the grooves on the draw valves. Lubricate the o-rings.
Step 15 Slide the fork of each draw handle into the slot of the draw valves, starting from the right. Slide the long pivot pin through the right and middle draw handles. Secure the left draw handle with the short pivot pin. Step 17 Slide the rear drip pan into the hole in the side panel. Figure 21 Note: This unit features adjustable draw handles to provide the best portion control, giving a better consistency quality to your product and controlling costs.
Step 2 Slide the small o-ring into the groove in the air orifice. DO NOT lubricate this o-ring. Air/Mix Pump Assembly This Model 8756 uses a single-stage pump. The purpose of the pump is to transfer specific amounts of air and mix to the freezing cylinder. Step 1 Assemble the piston by sliding the check band and the o-ring into the grooves on the piston. Do not lubricate the check band or o-ring. Figure 27 Step 3 Check the small hole in the air orifice to insure that it is not clogged.
Step 5 Insert the piston, air orifice end first, into the pump body and push upward. Step 6 Slide the two check bands and the two o-rings into the grooves on the liquid valve body. Do not lubricate the check bands or o-rings. Figure 32 Figure 30 Step 7 Insert the liquid valve body by aligning the steel button at the base of the liquid valve body with the cut-out groove at the bottom of the pump body. Note: The drive hole in the piston must be visible through the hole in the pump body.
Step 8 Slide the o-ring into the groove on the mix inlet fitting and lubricate the o-ring. Step 10 Secure the pump parts in position by sliding the keeper pin through the holes located at the bottom of the pump body. Figure 36 Figure 34 Step 11 Assemble the flare line and suction line. Attach the suction line to the barbed end of the mix inlet fitting and allow the weighted end to hang freely. Step 9 Insert the mix inlet fitting into the hole in the base of the liquid valve body.
Step 12 To secure the air/mix pump, place the pump collar over the pump body. (The cross holes of the pump collar will be on top.) Figure 40 Step 14 Place the diaphragm into its groove in the pressure switch cap. Figure 38 Align the drive hole in the piston to the ball crank of the motor reducer. At the same time, align the locating pin on the face plate.
Step 5 Attach the quick disconnect fitting of the pressure line to the other fitting on the mix inlet tube, just above the flare line. Allow the other end to hang free. Sanitizing Step 1 Prepare a pail of approved 100 PPM sanitizing solution (examples: 2-1/2 gal. [9.5 liters] of Kay-5R or 2 gal. [7.6 liters] of Stera-SheenR). USE WARM WATER AND FOLLOW THE MANUFACTURER'S SPECIFICATIONS. Step 2 Place the pail of sanitizing solution inside the mix cabinet.
Step 8 Press the PUMP key. A light will illuminate, indicating that the air/mix pump is operating. This action will cause the sanitizing solution to be pumped through the air/mix pump and out through the pressure line. After approximately 15 seconds, press the PUMP key. The light will extinguish and the pump will stop operation. Step 10 Place an empty pail beneath the door spout. Raise the prime plug. Figure 49 Step 11 Press the WASH and PUMP keys.
Step 12 When a steady stream of sanitizing solution is flowing from the prime plug hole in the bottom of the freezer door, press the PUMP key. This will de-activate pump operation. Push down the prime plug and allow the beater to agitate for 5 minutes. Step 14 When the sanitizer stops flowing from the door spout, close the draw valve. Press the WASH and PUMP keys to stop operation. Figure 51 Figure 53 Step 13 After 5 minutes, open the prime plug. Press the PUMP key.
Step 4 Install the funnel. Fill the mix tank with fresh mix. Priming Step 1 Place the mix tank and the cover in the mix cabinet. Step 2 Insert the prongs of the mix probe inside the mix tank. Connect the mix probe in the socket receptacle. Figure 56 Step 5 Remove the funnel and install the mix storage cover. Close the mix cabinet door. Step 6 Place an empty pail beneath the door spout and open the draw valve. With the prime plug still in the UP position, press the PUMP key.
Step 7 When a steady stream of mix is flowing from the prime plug hole in the bottom of the freezer door, press the PUMP key to stop operation. Figure 60 Repeat these steps for the other side of the freezer. Figure 58 Step 8 Once the stream of mix stops flowing from the prime plug hole, push down the prime plug. Rinse the prime plug hole area with water. Remove the pail and discard the mix and sanitizer. When the unit cycles off, the product will be at the correct viscosity.
Draining Product From the Freezing Cylinder Rinsing Step 1 Fill the empty pail in the mix cabinet with two gallons (7.6 liters) of cool, clean water. Place the free end of the suction line in the pail of water. Step 1 Press the AUTO and MIX REF keys to cancel freezer operation. Step 2 Disconnect the pressure line from the pressure switch and place it in the pail of water. Step 2 Open the mix cabinet door and remove the mix storage cover, the mix tank cover, the mix tank, and the mix probe.
Step 5 Place an empty pail beneath the door spout. Raise the prime plug and press the WASH and PUMP keys. Cleaning Step 1 Prepare a pail of approved 100 PPM cleaning solution (examples: 2-1/2 gal. [9.5 liters] of Kay-5R or 2 gal. [7.6 liters] of Stera-SheenR). USE WARM WATER AND FOLLOW THE MANUFACTURER'S SPECIFICATIONS. Step 2 Place the pail of cleaning solution inside the mix cabinet and insert the suction line.
Step 6 Place an empty pail beneath the door spout. Raise the prime plug and press the WASH and PUMP keys. Step 9 Place the power switch in the OFF position before disassembling the machine. Figure 68 Figure 66 Disassembly Step 7 When a steady stream of solution is flowing from the prime plug hole in the bottom of the freezer door, open the draw valve and draw off the remaining cleaning solution. MAKE SURE THE POWER SWITCH IS IN THE “OFF” POSITION.
Step 6 Return to the freezer with a small amount of cleaning solution. Use the black bristle brush to brush clean the rear shell bearings at the back of the freezing cylinders. Brush Cleaning Step 1 Prepare a sink with an approved cleaning solution (examples: Kay-5R or Stera-SheenR). USE WARM WATER AND FOLLOW THE MANUFACTURER'S SPECIFICATIONS. If an approved cleaner other than Kay-5r or Sterar-Sheen is used, dilute it according to the label instructions. IMPORTANT: Follow the label directions.
Section 7 Important: Operator Checklist j 5. Properly prepare the cleaning and sanitizing solutions. Read and follow the label directions carefully. Too strong of a solution may damage the parts and too weak of a solution will not do an adequate job of cleaning or sanitizing. Sanitize the freezing cylinder for 5 minutes. During Cleaning and Sanitizing ALWAYS FOLLOW LOCAL HEALTH CODES.
j 7. If your machine is air cooled, check the condensers for accumulation of dirt and lint. Dirty condensers will reduce the efficiency and capacity of the machine. Condensers should be cleaned monthly with a soft brush. Never use screwdrivers or other metal probes to clean between the fins. Note: For machines equipped with an air filter, it will be necessary to vacuum the filters on a monthly schedule. The Air/Mix Pump j 1.
Section 8 PROBLEM 1. No product is being dispensed. Troubleshooting Guide PROBABLE CAUSE REMEDY PAGE REF. a. Low on mix. The MIX OUT light is on. a. Add mix to the mix tank and press the AUTO key. 28 b. The power switch is in the OFF position. b. Place the power switch in the ON position and press the AUTO key. --- c. The beater motor is out on reset. c. Reset the freezer. d. Insufficient mix in the freezing cylinder. d. Refer to problem #2. --- e. Restriction in the door spout. e.
PROBLEM PROBABLE CAUSE REMEDY PAGE REF. 2. Insufficient mix in the freezing cylinder. (Cont'd.) d. Missing, defective, or no lubrication on the mix inlet fitting o-ring. d. Replace or evenly lubricate the o-ring on the mix inlet fitting. 23 / 41 e. The pump motor is not activated. e. Place power switch in OFF position. Push reset button on pump drive motor. Return power switch to ON position. Press the AUTO key. --- f. Pressure switch diaphragm installed incorrectly, or missing. f.
PROBLEM 4. Product is too soft. PROBABLE CAUSE REMEDY PAGE REF. a. Worn scraper blades. a. Replace scraper blades regularly. 41 b. Dirty condensers or air filters on air cooled units. b. Clean monthly. 35 c. Inadequate water supply on water cooled units. c. Check the water supply. Check water lines for leaks or kinks. 1/ 35 d. Inadequate air space around air cooled units. d. Allow adequate room for air flow across the condensers. Minimum of 3” (76 mm) clearance on all sides.
PROBLEM 8. Excessive mix leakage into the rear drip pan. 9. The drive shaft is stuck in the gear box coupling. 10. Freezing cylinder walls are scored. 11. The air/mix pump does not operate. Model 8756 PROBABLE CAUSE REMEDY PAGE REF. a. Worn or missing drive shaft seal. a. Install or replace the seal. 16/ 41 b. Improper lubrication of the drive shaft. b. Lubricate properly. c. Worn rear shell bearing. c. Contact a service technician to replace the rear shell bearing. --- d.
PROBLEM REMEDY PAGE REF. a. The machine is unplugged. a. Plug the machine into the wall receptacle. --- b. The circuit breaker is off or the fuse is blown. b. Turn the breaker on or replace the fuse. --- c. Low on mix. The MIX OUT light is flashing. c. Add mix to the mix tank and press the AUTO key. 13 d. The mix probe is not installed properly or is damaged. d. Check the mix probe installation. 28 e. The beater motor is out on reset. e. Reset the freezer. 13 f.
Section 9 PART DESCRIPTION Parts Replacement Schedule EVERY 3 MONTHS EVERY 6 MONTHS ANNUALLY Black Bristle Brush, 1” x 2” Inspect & Replace if Necessary Minimum Double Ended Brush Inspect & Replace if Necessary Minimum White Bristle Brush, 1” x 2” Inspect & Replace if Necessary Minimum White Bristle Brush, 9/16” x 44” Inspect & Replace if Necessary Minimum White Bristle Brush, 3” x 7” Inspect & Replace if Necessary Minimum Small White Bristle Brush, 1/8” Inspect & Replace if Necessary M
Section 10 Limited Warranty on Equipment TAYLOR COMPANY LIMITED WARRANTY ON FREEZERS Taylor Company, a division of Carrier Commercial Refrigeration, Inc. (“Taylor”) is pleased to provide this limited warranty on new Taylor-branded freezer equipment available from Taylor to the market generally (the “Product”) to the original purchaser only. LIMITED WARRANTY Taylor warrants the Product against failure due to defect in materials or workmanship under normal use and service as follows.
3. Replacement of wear items designated as Class “000” parts in the Taylor Operator’s Manual. 4. External hoses, electrical power supplies, and machine grounding. 5. Parts not supplied or designated by Taylor, or damages resulting from their use. 6. Return trips or waiting time required because a service technician is prevented from beginning warranty service work promptly upon arrival. 7.
Section 11 Limited Warranty on Parts TAYLOR COMPANY LIMITED WARRANTY ON TAYLOR GENUINE PARTS Taylor Company, a division of Carrier Commercial Refrigeration, Inc. (“Taylor”) is pleased to provide this limited warranty on new Taylor genuine replacement components and parts available from Taylor to the market generally (the “Parts”) to the original purchaser only. LIMITED WARRANTY Taylor warrants the Parts against failure due to defect in materials or workmanship under normal use and service as follows.
LIMITED WARRANTY EXCEPTIONS This limited warranty does not cover: 1. Labor or other costs incurred for diagnosing, repairing, removing, installing, shipping, servicing or handling of defective Parts, replacement Parts, or new Parts. 2. Normal maintenance, cleaning and lubrication as outlined in the Taylor Operator’s Manual, including cleaning of condensers or carbon and grease buildup. 3.
LIMITATION OF WARRANTY THIS LIMITED WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, CONDITIONS AND/OR REMEDIES UNDER THE LAW, INCLUDING ANY IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THE ORIGINAL OWNER'S SOLE REMEDY WITH RESPECT TO ANY PRODUCTS SHALL BE REPAIR OR REPLACEMENT OF DEFECTIVE PARTS UNDER THE TERMS OF THIS LIMITED WARRANTY.
Model 8756 47 013071 013072 013073 021101 023316 027647 050103 X34464 032444 BRUSH-REAR BRG 1“ D X 2” LONG X 14 BRUSH-DOUBLE ENDED BRUSH-DRAW VALVE 1" OD X 2" X 17" L BRUSH-FEED TUBE 9/16 OD BRUSH-MIX PUMP BODY-3" X 7" WHITE BRUSH-PRESSURE SWITCH BRUSH-SET CABLE A.-2 COND-24 IN-PUSH ON CABLE-RIBBON-POWER/RELAY-18 IN 013739 X22004 BRACKET A.
+ Available Separately Parts List 48 Model 8756 048627-27 COMPRESSOR AEA0415ZXD-AE580ET +RELAY-START-COMPRESSOR 012721 COUPLING-DRIVE 3/4 HEX X 1-7/8 2 037200 038145 +RELAY-START COMPRESSOR 052401-27 052197 +RELAY-START-COMPRESSOR +KIT-MOUNTING-COMPRESSOR 032424 031304 +CAPACITOR-START-216-259UF-250V DECAL-DEC-TAYLOR-TWIN-SS-CABINET 029439 +CAPACITOR-RUN- 35UF-370V 052397- 031790 +CAPACITOR-START - 161-193UF/250V COMPRESSOR CS18K6E-PFV (COPELAND) 012906 +CAPACITOR-RUN 20UF/440V C
+ Available Separately Model 8756 49 Parts List 3 033662 029639-BLK +SCREW-ADJUSTMENT-STAINLESS 050346 050347 SHOE-FRONT HELIX *REAR* SHOE-FRONT HELIX *FRONT* 045865 065471 FITTING DOOR INTERLOCK 038417-DVD DVD-OPS TRAIN VIDEO X30939 048901 DRYER-FILTER FASTENER-CLIP 1/4-20 U TYPE 8 049346 EVAPORATOR-12L X 4H X 1-7/8T X24816 DRYER-CAP. TUBE 014402 X18303 016272 X22387 016272 X22388 016137 DOOR A.-INS.MIX +O-RING-7/8 OD X .103W +VALVE A.-DRAW +O-RING-5/16 OD X .070W +ROD A.
+ Available Separately Parts List 50 Model 8756 X49463-2 KIT A.-TUNE UP-3 SPOUT-CAB 014218 014402 016272 034698 CAP-DESIGN 1.010"ID-6 POINT O-RING-7/8 OD X .103W O-RING-5/16 OD X .070W SEAL-DRAW VALVE X56200-6 X62253-27 KIT A.-MOTOR-FAN KIT A.-BARREL *TWIN SS X50350 KIT A.-BEATER-FRONT SHOES 020249 048526 DIAPHRAGM-PRESSURE SWITCH 027581 HOOD X32521 HOLDER-FUSE 300 VOLT PANEL MOUNT 036023 020143 HINGE-SELF CLOSING DOOR +SUPPORT A.-HINGE X25736 HINGE A.
+ Available Separately Model 8756 51 Parts List 021522-33 062253-27 MOTOR-1.5 HP MOTOR-FAN 95.3 CFM 2700 RPM 053481-27 03091327AS MOTOR-FAN 208-230V 50/60 HZ MOTOR-REDUCER 54 RPM-SS 028534-1 028752-M MAN-OPER 8752/8756/8757 +GUARD-FAN 047518 LUBRICANT-TAYLOR 4 OZ. 020940-16 TUBE-VINYL 3/16 ID X 1/16 038299 020021 LINE A.-FLARE 15" 030553 X27139 LINE A.-PUMP PRESSURE SOCKET-QD.
140814 Parts List + Available Separately 52 Model 8756 023425-50 ORIFICE 027504 X22879 X23956 023598 022015 028599 028600 PAN-DRIP 17-1/4"LONG PANEL A.-FRONT PANEL A.-LOWER SIDE PANEL-LOWER REAR PANEL-UPPER REAR PANEL-UPPER SIDE LEFT PANEL-UPPER SIDE RIGHT 020051 021276-8 021276-2 PIN-RETAINING PISTON X22345 PUMP A.-SOFT SERVE *CABINET* O-RING-2-1/8 OD X .139W-#225 027822 PULLEY-2AK74-5/8 021278 016403 PULLEY-2AK22 X .625-.6265 022502-4 X36267 PROBE A.
+ Available Separately Model 8756 53 Parts List 054703-03 042007-34 032607-27 050106-27 055492 010425 032564 RELAY-DPDT-24VAC-30A@277V RELAY-MTR START TI#4CR-2-645 RELAY-SPST-30 A-240V RELAY-START-COMPRESSOR SANITIZER-STERA SHEEN-GREEN SANITIZER-STERA SHEEN GREEN SHAFT-BEATER 048519 X49124 025707 023488 023487 032651 065409 X36615 SHROUD-CONDENSER *FRONT SHROUD A.-EVAPORATOR SPRING-COMP.970X.115X2.00 SPRING-RETURN RIGHT SPRING-RETURN LEFT SPRING-COMP.480X.047X1.
+ Available Separately Parts List 54 Model 8756 032190 038484 023487 023488 X39269 E-RING 1/4 PIN-PIVOT-DRAW SWITCH SPRING-RETURN LEFT SPRING-RETURN RIGHT SWITCH A.-DRAW-TWIN TWIST 035793 030132-27 016352-27 014533 TRANS.-240V PR1/24V SEC 10 VA TRANS.-CONT.-ANTICIPATOR 20 TRAY-DRIP 22-7/8L X 5-1/8W 034928 TANK-MIX 9-GALLON TAPERED BOTTOM TOOL-LIQ.VALVE BODY EXTRACTING 038750 X38755 TANK A.
+ Available Separately Model 8756 55 Parts List 024826 024824-SP 024825 022013 X23124 019330 032886 TRIM-BOTTOM MIX DOOR TRIM-FRONT LEFT TRIM-FRONT RIGHT TRIM-REAR CORNER TUBE A.-MIX INLET-SOFT SERVE +O-RING-13/16 OD X .103W +SEAL-INLET TUBE X49653 X18303 029406 044404 043232 047016 022665 046365 050900 VALVE A.-ACCESS - CABINET VALVE A.
WHT GRN/YEL GRN/YEL BRN MIX LEVEL PROBE BLK NC C BRN DRAW 8 1 A GRN/YEL SHK PUMP SET POINT A RED BLK MIX HOPPER TEMP BLK FAN MIX 2 BRN BLK/WHT SOFTECH CONTROL STANDBY TEMP MIX OUT PUMP BRL PROBE MIX LOW AUTO MIX 1 WASH STANDBY COLDER STANDBY MIX COLDER MEMBRANE SWITCHES SHK.TEMP/ VISCOSITY COLDER PANEL BLK LOGIC 5 N. O.