User's Manual

346
053566-58
11/12/13
YEL
BLK
YEL
BLK
RED/WHT
WHT
BLK
BLK
BLU/WHT
WHT
ORN
ORG/WHT
BRN
RED/BLK
BLK
RED/BLK
BLK
BLK
RED/BLK
BARREL 2
BARREL 1
BLK
BLK
BRN
RED
BLK
BLK
BLK
RED
BARREL
2
BIB
SWITCH
BARREL
2
HOPPER
FILL
SWITCH
THERMISTORS
PROBES
RIBBON CABLE SEE NOTE 2
WHT/BLK
BLK
LCD DISPLAY
RIBBON CABLE
SEE NOTE 2
RIBBON CABLE
SEE NOTE 2
RIBBON CABLE
SEE NOTE 2
WHT
PROXIMITY
SWITCHES
BARREL 2
BARREL 1
RIBBON CABLE SEE NOTE 2
RIBBON CABLE SEE NOTE 2
BARREL 1
KEYPAD
BARREL 2
KEYPAD
NOTE:
1. STATIC ELECTRICITY MAY CAUSE
DAMAGE TO SOLID STATE COMPONENTS.
ELIMINATE STATIC ELECTRICITY BY TOUCHING
GROUNDED UNIT BEFORE HANDLING SOLID STATE
COMPONENTS.
2. STRIPED WIRE ON RIBBON CABLES
MUST BE CONNECTED TO PIN 1
AT EACH END.
BRNBRN
BRN BRN
BARREL 2
SYRUP OUT
SWITCH
L1 L2
L2L1
LINE
LOAD
M
BLK BLK
W2
BLK
BRN
ORG/WHT
ORN
ORG/WHT
BRN
WHT
ORN
ORNBLK
BLK
WHT/BLK
41 1 4
H2O
PRESSURE
SWITCH
PRP/WHT
PRP/WHT
BRN
RED
BLK/YEL
BRN
YEL
BLK
YEL
BLK
BLK
BLK
WHT
BRN
PRP
PRP
WHT
WHT
WHT
WHT
WHT
WHT
WHT
WHT
WHT
BLK
BLK
RED
BLK
BLK
BLK
C02
PRESSURE
SWITCH
BARREL
1
HOPPER
FILL
SWITCH
BARREL
1
BIB
SWITCH
BARREL 1
SYRUP OUT
SWITCH
LEFT
HPCO
L1
N
BLK BLK
WHT/BLK
WHT
WHT
YEL
WHT
WHT
BLKBLK
BLK
RED
BLK
BLK
GRN/YELGRN/YEL
GRN/YEL
BLKBLK
WHT/BLK
5
6 1
2
4 1
BEATER MOTOR WIRING
YEL WHT
WHT/BLK
YEL WHT
WHT/BLK
WHT/BLK
WHT/BLK
YEL
GRN/YEL
WHT/BLK
M
BLKBLK
BLK
BLK
M
WHT
RED/WHT
WHT
WHT
WHT
RED
WHT
BLK/WHT
BLK
BLK
RIGHT
HPCO
WHT/BLK
WHT
GRN/YEL
WHT
WHT
GRN/YEL
WHT
BLK
BLU/WHT
L2
L3
BLK
GRN/YEL
BLK
GRN/YEL
GRN/YEL
BLK
BLK
BLK
BLK
BLK
BLK
BLK
C
NO
C
NO
GRN
BRN
BLK
BLU
BRN
BLK
BLU
WHT
RED
LED
BARREL 2
BLK/WHT
RED
BLU
LED
BARREL 1
WHT
WHT
BLU
RED
M
BLK BLK
CARBONATOR FILL SWITCH
WHT
15A
FUSE
CONTROL
ENCLOSURE(S)
GRN/YEL
BLK
WHT
BLK
BLK
GRN/YEL
START
1
3
MAIN
2
4
2C
THERMAL
O.L.
EXTRA
MAIN
6
5
RED 50 HZ
BLK 60 HZ
WHT COM
BRN
BRN
CAP
208/240 50/60 HZ
GE MOTOR SCHEMATIC
FIG. 1
1 2
1211
PRIMARY
SECONDARY
LEFT BEATER MOTOR
BARREL 1
COMP.
CONT.
COIL
BARREL
1
H20 SOL.
BARREL
1
SYR.SOL.
BARREL
1
CO2 SOL.
BARREL
2
CO2 SOL.
BARREL
2
H20 SOL.
BARREL
2
SYR.SOL.
BARREL 1
DEFROST
SOLENOID
4 3 2 1
1 2
J1
J10 J11
J7
J9
J5
J6
J4
J3
J2
GROUND FRAME
SECURELY
J6
CONTROL PCB A.
CONTROL
SWITCH
SPST
EMI FILTER
LEFT
COMPRESSOR
LEFT
COMPRESSOR
CONTACTOR
T1 L2T2L1
INTERFACE PCB A.
1 2 3 4 5 6 7 8 1 2
6 5 4 3 2 17
1 2
3
4
J14
J12J15J11
J5 J3 J1J4
J2
J10J9
L1
6 5 4 3 2 176 5 4 3 2 176 5 4 3 2 176 5 4 3 2 1
1 2 3 4 5 6 7 8
L2
J16 J13
J8
W1
1 2 3 4
J7
4 3 2 1
5 3 1
W1
LEFT
COMPRESSOR
CONTACTOR
MAGNATEK-CENTURY
LEESON
RIGHT BEATER MOTOR
RIGHT
COMPRESSOR
RIGHT
COMPRESSOR
CONTRACTOR
T1
L2
T2
L1
RIGHT
COMPRESSOR
CONTRACTOR
COMP.
CONT.
COIL
BARREL 2
DEFROST
SOLENOID
BARREL 2
L3T3
LEFT
COMPRESSOR
CONTACTOR
L3
T3
RIGHT
COMPRESSOR
CONTRACTOR
LINE
COPELAND COMPRESSOR WIRING
BLOWER
(FIG 1)
X1
A B
PUMP
1
11
2
12
EMPTY (JUMPER USED FOR W.C. ONLY, SOFTWARE VER. 2.04)
EMPTY - H20 PRESSURE SWITCH ACTIVE/JUMPER - H20 PRESSURE SWITCH BYPASSED
EMPTY
SERVICE/TEST ONLY
4 3
6 5
8 7
910
INTERFACE PCB A. W1 JUMPER BLOCK DETAIL
JUMPER BLOCK SHOWN ABOVE WOULD INDICATE A UNIT CONFIGURED
AS A MODEL 346, AIR COOLED WITH A H20 PRESSURE SWITCH.
COMPRESSOR
TERMINALS
EMPTY
EMPTY (JUMPER USED FOR MODEL 346, SOFTWARE VER. 2.04).
OUT
BRN OUT
PCB A.
IN IN
OUT
CONT.
TRANS.