TABLE OF CONTENTS: TABLE OF CONTENTS ................................................................................................................... 1 SPECIFICATIONS .......................................................................................................................... 2 DISPLAY ........................................................................................................................................... 3 BUTTON DESCRIPTION ................................................
SPECIFICATIONS Model TE30WD Capacity 0-10 lb x 0.05 oz/10-30 lb x 0.1 oz 0-5 kg x 0.002 kg(2 g)/5-15 kg x 0.005 kg (5 g) 30 lb x 1/8 oz Weight Unit lb:oz(decimals)/lb:oz(fractions)/kg LCD Readout 1” LCD readout Dimensions 14” x 14” x 1.6” Buttons ON/OFF, HOLD, Unit, Tare, Channel Power Supply 10-AA batteries(6 for base,4 for remote, not included.
DISPLAY BUTTON DESCRIPTION Press to turn the scale ON or OFF. Press to ‘Tare’ (zero) the weight of any item while weighing. Press to ‘Hold’ the weight on the screen. Press to switch between lb:oz and kg units of measurement. kg ←→ lb:oz Press to reset the scale to zero(TARE function)if the scale does not show zero automatically. Icon flashes when scale is ready for a weighing. Stability display: If the display shows‘o’,the weight is stable on the scale. If the display shows ‘ ’, the weight is unstable.
PREPARING SCALE FOR WEIGHING Before Weighing 1. Please select the scale’s channel to match the wireless display. (The scale’s channel indicator is located on the scale’s base; please remove the rubber stopper to access the channel indicator.)For example: If the wireless display is using Channel-1, select Channel-1 for the scale.(Please see Page 6 for instructions for selecting platform channels.) 2. Press the ON/OFF button to turn on the scale. 3.
CHANGING THE WIRELESS DISPLAY’S CHANNEL Press the button to select the wireless display channel. Channel numbers (1, 2, 3) are shown on the left hand side of the display. When a channel is selected,a triange icon points to the selected channel. For example- If Channel-1 is selected, the triange icon points to ‘1’.
SELECTING THE SCALE PLATFORM’S CHANNEL To select the scale platform’s channel, first turn off the scale base and wireless display units. Then use the dip switch, which is located on the bottom of the scale under the rubber stopper. The dip switch has four pins marked ‘1, 2, 3, 4’ (Pin-4 is not active; only 3 channels are available for use.) To select a channel, move the pin toward the ‘ON’ mark (pictured below). For example- To select Channel-1 for the scale, move Pin-1 towards the ‘ON’ mark.
USING THE TARE FUNCTION The Tare Function allows the user to zero the scale to cancel out the weight of a container, thus giving the weight of the item being weighed. Press the ON/OFF button to turn on the scale. Place the containter on the scale platform. Press the ‘TARE’ button after the weight stabilizes and stable sign displays. The display will reset to ‘0’. Place the item to be weighed on the platform(without removing the ‘tared’ container).
ACTIVATING/ DEACTIVATING TOUCH LESS TARE FEATURE Press to move right or down as shown in setup flowchart.
TABLE-TOP STAND AND WALL MOUNTS You may stand the scale platform on a table. Adjust the angle of the wireless display for easy viewing. Table top display: Wall display: The wireless display may be mounting material included. 1. Screw the screws to the wall as shown. 2. Push the wireless display onto the well. 9 mounted to a wall.
POWER SOURCES If displays on the LCD, please use the included Taylor adapters or replace the batteries. Insert an adapter into the bottom of the wireless display and the scale base. Indicator - AC Jack Connector Weighing PlatformAC Jack Connector This scale’s weighing platform and wireless dislay require separate electric power. Before using the scale, please make sure that both the scale base and wireless display have batteries correctly installed or both adapters correctly plugged in.
ERROR MESSAGES Message Description Low battery indicator for wireless display: This warning indicates the batteries for the wireless display are low. Please replace all the batteries or use the AC adapter for operation. Low battery indicator for scale base: This warning indicates the batteries for the scale base are low. Please replace all batteries or use the AC adapter for operation. EEPROM error for wireless display: The programming for the wireless display has an error.Please contact customer service.
FEDERAL COMMUNICATIONS COMMISSION (FCC) STATEMENT Transmission Collision Signals from other household devices, such as doorbells, home security systems and entry controls, may interfere. This is normal and does not affect the general performance of this product. The transmission will resume once the interference recedes. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
Precautions This scale is engineered to give you years of satisfactory service if you handle it carefully. Here are a few precautions: 1. Always read instructions thoroughly to ensure that you have the full benefit of all the unit's features. 2. DO NOT immerse units in water, as doing so will cause damage to internal components and void the warranty. If you spill liquid on it, dry it immediately with a soft, lint-free cloth. 3. DO NOT clean the units with an abrasive or corrosive material.
One Year Limited Warranty Taylor warrants this product to be free from defects in materials or workmanship for one (1) year from date of original purchase. It does not cover damages or wear resulting from accident, misuse, abuse, commercial use, or unauthorized adjustment and/or repair. If service is required, do not return to distributor. For service, call between 7:30 AM and 4:30 PM, Mountain Standard Time, Monday through Friday.