Algorithm Manual Revision 4

MD 5.1
104 System 6000 MKII Algorithms – Firmware version 6.5.0
Bypass Limiter
Press to Bypass the Limiter section of the 5.1
algorithm.
MD5.1 algorithm – soft clip page
MD5.1 algorithm – soft clip page
Soft Clip
Full Range Softclip
Range: -6dB to Off
Softclipper Threshold setting after the Compres-
sor for the five multiband channels. Threshold
is always relative to 0dBFS (Not the Reference
Level).
LFE Softclip
Range: -6dB to Off
Softclipper Threshold setting for the LFE chan-
nel only.
MD5.1 algorithm – full limit page
MD5.1 algorithm – full limit page
Threshold
Range: -12dB to Off
-6 to 0dB in 0.1dB increments
-12 to -6 in 0.5dB increments
Brickwall limiter for the five multiband channels.
Threshold is always relative to 0dBFS. LED on
each Output meter indicates when Limiter is ac-
tive.
Release
Range: 0.01 to 1.00 seconds
Release time for the Limiter.
Ceiling
Range: -0.10dB to 0dB
Fine-tuning parameter setting the Ceiling for the
Limiter.
The Ceiling parameter prevents the Output sig-
nal from exceeding the adjusted Limiter Thresh-
old. It can be used to “hide” overloads to down-
stream equipment, but it does not remove the
distortion associated with an over.
MD5.1 algorithm –
LFE limiter page
MD5.1 algorithm – LFE limiter page
LFE Limiter
Threshold
Range: -12 to +3dB
-6 to + 3 in 0.1dB increments
-12 to -6 in 0.5dB increments
Brickwall limiter for the LFE channel. Threshold
is always relative to 0dBFS. LED on each Output
meter indicates when limiter is active.