7. 3 System/ I/O
Go to Frame/System/ I/O.
Use this page to:
• Display clock status.
• Display input state.
• View the clock settings.
Clock Status
• LOCK indicator – The Lock status eld shows the top-level lock status of an
incoming MADI stream.
• When Reverb TwentyFour is locked to an acceptable MADI stream,
“Lock” is shown.
• When no acceptable MADI stream is available, “No Lock” and a red LED
will be shown in this eld.
• Sample Rate indicator – When the Reverb TwentyFour is locking to an
incoming MADI stream, the sample rate in Hz will be shown. If the
Reverb TwentyFour is not locking, the indicator eld will read “N/A.
Input State
• MADI 1-64 – The LED below this text will indicate green when
MADI input is present .
Clock Setup
• Clock Master – The Reverb TwentyFour can only sync to the external
MADI input.
• Internal Rate – If the MADI input is lost, it will revert to the internal clock at
48 KHz = “Freewheeling.
• Sync Source – The Reverb TwentyFour can only sync to MADI.
• Ext.Clk Accept Rate – The Reverb TwentyFour can only sync at 48 kHz.
• Clock Freewheeling – If the unit is freewheeling, then the audio output
is unmuted.
7.4 System/ Setup/ Version
Go to Frame/System/Setup/Version.
Use this page to:
• Show the unit's unique factory serial number.
• Show the TC Icon software version number.
• Show the unit's SW version number (i.e. the rmware version).
This page also has 2 buttons in the lower section as follows:
• Update Version Information – press the circular button in the lower left,
to update the information, if for example, you have updated the TC Icon
software or the Reverb TwentyFours rmware.
• Reset to Defaults – press the circular button in the lower right to reset the
Reverb TwentyFour to its factory default settings. Any user presets will be
saved and not lost.
18 REVERB TWENTYFOUR Owner’s Manual