Manual
Table Of Contents
- Important Safety Instructions
- Legal Disclaimer
- Limited warranty
- 1. Introduction
- 2. TC Icon software installation
- 3. Controls and Connectors
- 4. Overview
- 5. Setting up
- 6. Quick Setup
- 7. Basic operation with the TC Icon software
- 8. Using the Library
- 9. TC Icon Setup
- 10. Using Reverb TwentyFour
- 11. Main page
- 12. Grid page
- 13. Setup page
- 14. Rev page
- 15. Trim page
- 16. Factory presets
- 17. System/ Remote
- 18. Acoustics Enhancement
- 19. Specifications
GPI Voltage Windows
In the table below, voltages outside the limits mentioned are to be considered
invalid. No action is taken if invalid measurements are made. GPI recall action
resumes when a stable, valid measurement is detected again.
Mode
User
Preset
No
Scaled
Target
/ Vs
Min
typ
/ V
Target
typ / V
Max
typ / V
RL3 RL2 RL1
1 of 2 1
1.000
(idle)
2.67 3.30 3.30 open
2 0.000 0.00 0.00 0.51 closed
1 of 4 1
1.000
(idle)
3.20 3.30 3.30 open open
2 0.689 2.18 2.28 2.38 closed open
3 0.548 1.71 1.81 1.91 open closed
4 0.439 0.00 1.45 1.55 closed closed
1 of 8 1
1.000
(idle)
3.20 3.30 3.30 open open open
2 0.826 2.63 2.73 2.83 closed open open
3 0.689 2.18 2.28 2.38 open closed open
4 0.602 1.93 1.99 2.05 closed closed open
5 0.548 1.75 1.81 1.87 open open closed
6 0.491 1.56 1.62 1.68 closed open closed
7 0.439 1.40 1.45 1.50 open closed closed
8 0.402 0.00 1.33 1.38 closed closed closed
Notes:
• “Idle” refers to the state when no input is connected, or when the input is
left oating.
• Rather than absolute voltage measurements, the windows are dened as
a fraction of the supply voltage. This voltage can be measured with a high
impedance DMM on the D-SUB pin 5 or 10.
• The table shows values as a fraction of the supply voltage, and, as a
guideline, typical voltages when the supply is 3.30 V. (If the supply voltage
is for example 3.315 V, the table should be corrected by multiplying these
values by 3.315/3.3).
44 REVERB TWENTYFOUR Owner’s Manual