Manual

3. Controls and Connectors
(3)
(5)
(6)
(7)
(8)
(13) (9)
(1) (2)
(11)
(4) (10) (11) (12)
(1) RACK MOUNT EARS – allow the unit to be mounted into a standard
1U rack. Be kind and use washers and the correct rack screws to hold
the unit securely in your rack.
(2) HANDLES – these allow the unit to be carried and easily pulled in and
out of the rack.
(3) RUNNING LED – this LED indicates the status of the Reverb TwentyFour:
Running Led Status TC Icon message
O
Startup until all
processors are running
N/A
Green
Startup completed, and
the unit is ready
Running OK
Red System Error
Not running,
system error
(4) POWER LED – this is Green when AC power is applied to the unit.
(5) NET LED – The Net LED indicates the status of the network connection to a
computer running TC Icon software or a hardware TC Icon device.
Net Led Status TC Icon message
O
No computer or TC icon
device connected
N/A
Green
One or more TC Icons or
computers connected
Net – This Icon(1),
2 Icons/ Apps(2) …
8 Icons/Apps(8)
Running OK
O/
Green,
Yellow,
Red
Frame identication –
see "Frame identication
parameter" on page 17
Net LED will blink various
colors as set by the
TC Icon software, so you
can easily identify the
Reverb TwentyFour when
operating multiple units
(6) BYPASSED LED – this LED will turn on when the Reverb TwentyFour is in the
BYPASS mode, as set by the TC Icon controller software on your computer
(see page 20), or by using the hardware TC Icon remote device. No reverb will
be added to any of the audio inputs when the unit is in Bypass mode.
(7) SYNC LED – this LED indicates if synchronization to the signal source
has been achieved.
Sync Led Status TC Icon message
O
Startup until I/Os are up
and runnning
N/A
Green
Sync OK + all inputs OK
(No sample slips/repeats)
Inputs OK
Yellow Slip/repeat observed Input Slip
Red No valid clock available No Clock
(8) RESET BUTTON – The Reset button on the front panel can be used to
reset the IP address of a Reverb TwentyFour unit, or to reset Ethernet
communication between the unit and a computer when a communication
error has occurred.
Resetting the IP address
• On the rear panel, make a note of the unit's serial number and
write it down here:
• Switch o the Reverb TwentyFour unit by disconnecting
AC power to the unit.
• Gently insert a straightened paper clip or a similar object into the small
Reset hole on the front panel, until it touches the button behind the
panel, and then keep it holding down gently.
• Reconnect the AC power to the unit, while still holding the straightened
paper clip onto the Reset button.
• The Reverb TwentyFour unit will then boot using its default IP address as
follows: 192.168.1.[xx], where [xx] is the last two digits of the device’s
serial number as printed on the rear panel.
192.168.1_ _
9 REVERB TWENTYFOUR Owner’s Manual