User Instructions

24
HBM: Business Document
12 Specifications
Type
Customized flexplate
MPZ1901037
Nominal torque M
nom
N·m
800
Measurement bandwidth
kHz
1
Sensitivity tolerance (deviation of the
actual output quantity at M
nom
from the
nominal (rated) sensitivity)
%
±1
Thermal effects per 10 K in the nominal
(rated) temperature range on the output
signal, relative to the actual value of the
signal spread
%
< ± 0,1
Linearity deviation including hysteresis,
relative to the nominal (rated) sensitivity
%
< ± 0,1
Rel. standard deviation of repeatability
%
< ± 0,05 (typical ± 0,03)
Protection class acc. EN 60529
IP 54
Nominal (rated) temperature range
(continuous)
°C
+10 ... +120
Short time operating temperature
°C
-10 ... +125
Storage temperature range
°C
-20 ... +120
Temperature range of evaluation unit
°C
-20 … +75
Load limits
1)
Limit torque
%
150
Max. limit load of measuring body
2)
%
200
Breaking torque (static)
%
tbd
Longitudinal limit force (static)
N
tbd
Lateral force limit (static)
N
tbd
Bending limit moment (static)
N·m
tbd
Maximal speed
rpm
7000
Balancing quality
G
2,5
1) Each type of irregular stress (bending moment, lateral or longitudinal force, exceeding nominal (rated) torque) can only be
permitted up to its specified static load limit, provided none of the others can occur at the same time. If this condition not met, the
limit values must be reduced. If 30% of the bending limit moment and lateral limit force occur at the same time, only 40% of the
longitudinal forces is permissible and the nominal (rated) torque must not be exceeded. The permissible bending moments,
longitudinal forces and lateral forces can affect the measurement result by approx. 1% of the nominal (rated) torque. The load
limits only apply for the nominal (rated) temperature range. At temperature <10°C, the load limits must be reduced by approx. 30%
(viscosity reduction).
2) The data refer to static loading of the measuring body, not the screw connections.
3) The nominal (rated) torque must not be exceeded