Full Product Manual

The standard Power Unit for your lifts is 220
volt,60HZ,single phase. All wiring must be
performed by a certied electrician only.
SEE WIRING INSTRUCTIONS AFFIXED
TO MOTOR FOR PROPER WIRING
INSTRUCTIONS.
DO NOT run Power Unitwith no oil.Damage to pump
can occur.
The Power Unit must be kept dry. Damage to
Power Unit caused by water or other liquids such as
detergents,acid etc... is not covered under warranty.
Operate lift only between temperatures of 41°-104°F.
Improper electrical hook-up can damage motor and will
not be covered under warranty.
Motor can not run on 50HZ without a physical change
in motor.
Use a separate breaker for each Power Unit.
1. Install the 90-degree Hydraulic Fitting to the
POWER PORT and the 90* return air Line Fitting to
the RETURN PORT of the POWER UNIT and connect
the House as described below.It will be necessary
to remove the shipping plugs from both ports prior to
installing the Fittings.
NOTE:
Check the Power Unit to determine proper connection
ports for Power and Return lines.
It will be necessary to remove shipping plugs from both
ports prior to installing Fittings.
STEP 8
(Routing Hydraulic Hoses)
Power Port
90* O-ring
Fitting
Air Valve
Mounting
Bracket
Vibration
Dampener
M8 x 20mm Hex Head
Bolts at Washers &
Nylon Nuts x Four
Flex Tube
Bracket Assy
1. Mount the Power Unit to the Mounting Bracket
using the M8 Hex Head Bolts and Nylock Nuts
then ll the reservoir with 12 quarts of 10-WT
hydraulic oil.
DO NOT PERFORM ANY MAINTENANCE OR
INSTALLATION OF ANY COMPONENTS WITH
OUT FIRST ENSURING THAT ELECTRICAL
POWER HAS BEEN DISCONNECTED AT
THE SOURCE OR PANEL AND CANNOT BE
RE-ENERGIZED UNTIL ALL MAINTENANCE
AND/OR INSTALLATION PROCEDURES ARE
COMPLETED.
STEP 7
(Power Unit Installation)
ALL WARNING MUST BE PERFORMED BY A
LICENSED ELECTRICIAN
DANGER
DANGER
WARNING!