2. Install the 90-degree Hydraulic Fitting in the
port at the ram end of the Cylinder. On the pipe
thread side of the Fitting it is recommended to
use Teon Tape or pipe sealer. DO NOT USE
TEFLON TAPE on the JIS ared end.
5. Connect Hoses as shown below making sure
to pass through the retaining rings. MAKE SURE
HOSES ARE KEPT CLEAR OF CABLES.
6. Run the Power Unit Hydraulic Hose. (90
degree End towards HPU) and the Return Air Line
through the Flex Hose to the Power Unit.
7. Connect the Power Unit Hydraulic Line to the
90 degree Power Unit Fitting. Connect the Return
Air Line Hose to the 90 degree Return tting.
3. Install the 90-degree Air Line Fitting in the
port at the base end of the Cylinder. On the pipe
thread side of the Fitting it is recommended to use
Teon Tape or pipe sealer.
4. Install one end of Flex Hose to into hole in the
POWERSIDE RUNWAY adjacent to the power
unit. Install the other end of the Flex Hose to the
Flex Hose Bracket Assembly. Tighten the Plastic
Nut securely.
power
run the power unit
hydraulic hose (90
end) and the return
air line hose through
the ex hose to the
hydraulic power unit.
air 90
tting
retaining rings
ex hose
power
ex hose
M36x2 plastic
nut
power unit
hydraulic hose
TORIN COMMERCIAL EQUIPMENT
33 REV 190425