Full Product Manual

1. Have a certied electrician run the power
supply to motor.Refer to the data plate found on
the motor for proper power supply and wire size.
RISK OF EXPLOSION!
This equipment has internal arcing or parts
that may spark and should not be exposed to
ammable vapors.Motor should not be located
in a recessed area or below oor level.NEVER
expose motor to rain or other damp environments.
DAMAGE TO MOTOR CAUSED BY WATER IS
NOT COVERED UNDER WARRANTY.
IMPORTANT NOTE:
CAUTION Never operate the motor on line
voltage less than 208V.Motor damage may occur
which is not covered under warranty .Have a
certied electrician run appropriate power supply
to motor. Size wire for 25amp circuit.See Motor
Operating Data Table.
IMPORTANT:Use separate circuit for each power
unit.Protect each circuit with time delay fuse or
circuit break-er. For single phase 208-240V,use
25amp fuse.
Three phase 208-240V,use 25 amp fuse.For three
phase 400V and above,use 15amp fuse.All wiring
must company with NEC and all local electrical
codes.
STEP 10
(Power Unit Hook Up)
DANGER
POWER UNIT
Push Button Switch
PRESS TO PAISE
Wiring Scenmatic
Lowering Handle
PRESS TO LOWER
LIFT
Filler Cap FILL
WITH 12 QTS 10
WT HYDRAULIC
FLUID
Reservoir
2. Fill the Power Unit with hydraulic oil. Remove the oil
vent cap from the power unit and ll the reservoir. Use a
non-foaming, non-detergent hydraulic uid Ten Weight
(Hydraulic Oil ISO AW32). The unit will hold approximate-
ly 4 to 5 gallons depending on tank size dierent amounts
of uid may be required.
Flash Point (°F): 350
ISO Viscosity Grade (ISO-VG):3 2
Maximum Operating Temperature (° F): 300
Plastic Safe:Y es
Pour Point (°F): -30
Hydraulic Oil ISO AW32 Attributes:
DO NOT PERFORM
ANY MAINTENANCE OR
INSTALLATION OF ANY
COMPONENTS WITH OUT
FIRST ENSURING THAT
ELECTRICAL POWER HAS
BEEN DISCONNECTED AT
THE SOURCE OR PANEL AND
CANNOT BE RE-ENERGIZED
UNTIL ALL MAINTENANCE
AND/OR INSTALLATION
PROCEDURES ARE
COMPLETED.