Full Product Manual

TOP LOCK
Position
All cable nuts MUST be tightened on each
end until there is at least one inch of threads
protruding through the nut. Failure to do so could
result in serious injury or death.
There will be initial stretching of the cables in the
beginning and/or with increased loads. Adjust
the Cables as outlined above a week after rst
use,then every three to six months thereafter
depending on usage and/or to compensate for
stretch.
8. After connecting the air supply,press the PUSH
BUTTON AIR VALVE and check that all Safety
Locks are functioning properly. Lower the lift by
pressing the push button air valve and power unit
lowering valve simultaneously.
NOTE:
WARNING
9. Run the lift up and down at least three times,
BEFORE ANCHORING THE LIFT DOWN. This is
to bleed the air out of the cylinder and power unit
and to help align the lift.
10. Check that lift is square and aligned to
measurments before drilling anchor bolts.
11. Align as needed.
TORIN COMMERCIAL EQUIPMENT
38 REV 190425