Full Product Manual

TROUBLESHOOTING
LIFT WILL NOT RAISE
Air is in the oil
Check for proper oil level. The oil level should be up to the bleed screw in the reservoir
with the lift all the way down.
Bleed cylinders. See Installation Manual
Oil seal damaged or cocked. Replace oil seal around pump shaft.
Inlet screen clogged. Clean inlet screen or replace
Cylinder is binding
Contact Customer Service.
Cylinder leaks internally
Contact Customer Service
Lift does not raise and lower
smoothly
Reposition vehicle for a more even weight distribution
Check the four inside corners of the two columns for roughness. Any rust or burrs must
be removed with emery cloth.
Lubricate the four corners with heavy duty bearing grease.
Use a level to check the columns for vertical alignment both side to side and front to
back. Shim the columns as necessary per the Installation Instruction section of this
manual.
Check the oil level
Inspect that there is no air in the hydraulic lines. Bleed the hydraulic system as
described in the Installation Instruction section of this manual.
Lowering valve is leaking
Contact Customer Service
Motor runs backwards
Check if motor is wired correctly. Compare wiring of motor to electrical diagram on
drawing.
Check wall outlet voltages and wiring. Make sure unit and wall outlet are wired
properly.
Contact Customer Service
Motor run backward under pressure
Contact Customer Service
Power Unit will not stop running
Switch is damaged. Turn off power to the lift and replace switch
Pump is damaged
Contact Customer Service
Pump will not prime
Check for proper oil level. The oil level should be up to the bleed screw in the reservoir
with the lift all the way down.
Flush release valve to get rid of. Hold release handle down and start unit allowing
possible contamination it to run for 15 seconds.
Oil seal damaged or cocked. Replace oil seal around pump shaft.
Replace with new part.
Check pump-mounting bolts. Bolts should be 15 to 18 ft. lbs.
Inlet screen clogged. Clean inlet screen or replace.
Check wall outlet voltages and wiring. Make sure unit and wall outlet are wired
properly.
Contact Customer Service
Relief valve leaks
Contact Customer Service
Voltage to the motor is incorrect
Check if motor is wired correctly. Compare wiring of motor to electrical diagram on
drawing.
Check wall outlet voltages and wiring. Make sure unit and wall outlet are wired
properly.
Contact Customer Service
The power unit does not run
Check electrical supply breaker or fuse
Check to see if limit switch is being contacted by a tall vehicle
Check micro-switch and connections in motor control box
Check voltage to the motor
Check micro-switch and connections on the overhead switch
The power unit runs but does not
raise the lift
Check the oil level
Check that the lowering valve is not stuck open
Check the connections and components on the suction side of the pump
The power unit raises the lift empty
but will not lift a vehicle
Make sure the vehicle is not above the rated capacity of the lift
Make sure the vehicle is positioned properly
Clean the lowering valve by running the power unit for 20 seconds while holding the
lowering valve open
Check the motor voltage
TORIN COMMERCIAL EQUIPMENT
62 REV 190425