Model: TCLSS09 (2.5kW Cooling / 2.6kW Heating) TCLSS12(3.2kW Cooling / 3.2kW Heating) TCLSS18 (5.0kW Cooling / 5.2kW Heating) TCLSS24(7.0kW Cooling / 7.5kW Heating) TCLSS28 (7.8kW Cooling / 8.
CONTENTS SAFETY PRECAUTIONS ....................................................................................................1 NAMES OF PARTS .................................................................................................................4 INDOOR UNIT DISPLAY .........................................................................................................5 EMERGENCY FUNCTION & AUTO-RESTART FUNCTION ..............................................6 REMOTE CONTROLLER ................
SAFETY RULES AND RECOMMENDATIONS FOR THE INSTALLER Do not install the appliance at a distance of less than 50 cm from inflammable substances (alcohol, etc.) Or from pressurised containers (e.g. spray cans). Read this guide before installing and using the appliance. During the installation of the indoor and outdoor units the access to the working area should be forbidden to children. Unforeseeable accidents could happen.
SAFETY RULES AND RECOMMENDATIONS FOR THE USER Never remain directly exposed to the flow of cold air for a long time. The direct and prolonged exposition to cold air could be dangerous for your health .Particular care should be taken in the rooms where there are children , old or sick people. Do not try to install the conditioner alone; always contact specialized technical personnel. Cleaning and maintenance must be carried out by specialised technical personnel.
SAFETY RULES AND PROHIBITIONS Do not bend , tug or compress the power cord since this could damage it. Electrical shocks or fire are probably due to a damaged power cord. Specialised technical personnel only must replace a damaged power cord. Do not climb onto or place any heavy or hot objects on top of the appliance. Do not use extensions or power board. Do not direct the airflow onto plants or animals. Do not leave windows or doors open for long when the air conditioner is operating.
NAMES OF PARTS INDOOR UNIT No.
INDOOR UNIT DISPLAY 1 3 2 5 4 /O 1 5 2 2 1 3 4 4 5 3 4 3 2 1 3 4 5 1 2 3 4 5 3 1 No. 2 2 3 4 Led Function 1 POWER This symbol appears when the unit is power on 2 SLEEP SLEEP mode 3 Temperature display (if present) /Error code (1) Lights up during Timer operation when the air conditioner is operational (2)Displays the malfunction code when fault occurs. 4 TIMER Lights up during Timer operation.
EMERGENCY FUNCTION & AUTO-RESTART FUNCTION AUTO-RESTART FUNCTION The appliance is preset auto - restart function by manufacturer. In case of a sudden power failure, the module memorizes the setting conditions before the power failure. when the power restores, the unit restarts automatically with all the previous settings preserved by the memory function. ON / OFF POWER SLEE P TIMER RUN Emergency button To deactivate the AUTO-RESTART function ,proceed as follows: 1.
REMOTE CONTROLLER No. Button Function 1 (TEMP UP) Press it to increase temperature / time setting. 2 (TEMP DN) Press it to decrease temperature/ time setting. 3 4 ON/OFF FAN Press it to start or stop operation. To select the fan speed of auto/low/mid/high 5 TIMER Press it to set auto-off timer.
REMOTE CONTROLLER Remote controller DISPLAY Meaning of symbols on the liquid crystal display No.
REMOTE CONTROLLER Replacement of Batteries Remove the battery cover plate from the rear of the remote controller, by sliding it in the direction of the arrow. Install the batteries according the direction (+and -)shown on the Remote Controller. Reinstall the battery cover by sliding it into place. + Use 2 LRO 3 AAA (1.5V) batteries . Do not use rechargeable batteries . Replace the old batteries with new ones of the same type when the display is no longer legible.
OPERATING INSTRUCTIONS The air sucked by the fan enters from the grill and passes through the filter, then it is cooled/dehumidified or heated through the heat exchanger. Filter Heat Exchanger The direction of the air outlet is motorized up and down by flaps, and manually moved right and left by the vertical deflectors, for some models, the vertical deflectors could be controlled by motor as well. Fan “SWING” CONTROL OF THE AIR FLOW The air outlet flow is uniformly distributed in the room.
OPERATING INSTRUCTIONS COOLING MODE COOL COOL The cooling function allows the air conditioner to cool the room and at the same time reduces Air humidity. FEEL COOL DRY FAN HEAT To activate the cooling function ( COOL ) , press the MODE button until the symbol ( COOL ) appears on the display. C AUTOQUIET POWERFUL hr DELAY OFF ON C h ON HEALTHY TIMER ON/OFF 1 The cooling function is activated by setting the button or at a temperature lower than that of the room.
OPERATING INSTRUCTIONS ON TIMER MODE----TIMER ON ON TIMER To set the time of the air conditioner TIMER To program the automatical switching-on time, the appliance should be power off. Press TIMER at the fist time , set the temperature with pressing the button or ; Press TIMER at the second time , set the rest time with pressing the button or ; Press TIMER at the third time, confirm the setting, then the rest time to next automatical switching-on could be read on the display.
OPERATING INSTRUCTIONS FAN MODE FAN FAN The conditioner works in only ventilation. To set the FAN mode , Press MODE ( FAN ) appears in the display. FEEL COOL DRY FAN HEAT until C AUTOQUIET POWERFUL hr DELAY OFF ON FAN SPEED AIR SWING C h ON HEALTHY TIMER While pressing FAN button the speed changes in the following sequence: LOW/ MEDIUM/HIGH /AUTO in FAN mode. The remote control also stores the speed that was set in the previous mode of operation.
OPERATING INSTRUCTIONS I FEEL MODE FEEL Automatic mode. I FEEL To activate the I FEEL (automatic) mode of operation, press the MODE button on the remote controller until the symbol ( I FEEL ) appears on the display. In I FEEL mode the fan speed and the temperature are set automatically according to the room temperature (tested by the temperature sensor which is incorporated in the indoor unit). FEEL COOL DRY FAN HEAT C .
PROTECTION The air conditioner is programmed for comfortable and suitable living conditions, if it is used in abnormal conditioner as below, certain safety protection features might come into effect. For T1 Climate condition models: No.
INSTALLATION MANUAL---Selecting the Installation Place Install the indoor unit on a strong wall that is not subject to vibrations. The inlet and outlet ports should not be obstructed:the air should be able to blow all over the room. Do not install the unit near a source of heat , steam,or flammable gas. Install the unit near an electric socket or private circuit. Do not install the unit where it will be exposed to direct sunlight.
INSTALLATION MANUAL---Installation of the Indoor unit Before starting installation, decide on the position of the indoor and outdoor units, taking into account the minimum space reserved around the units Do not install your air conditioner in a wet room such as a bathroom or laundry etc The installation site should be 250cm or more above the floor. To install, proceed as follows: 50 Installation of the mounting plate 1 Always mount the rear panel horizontally and vertically 2.
INSTALLATION MANUAL---Installation of the Indoor unit Refrigerant piping connection 1 The piping can be run in the 3 directions indicated by numbers in the picture . When the piping is run in direction 1or3, cut a notch along the groove on the side of the indoor unit with a cutter. Run the piping in the direction of the wall hole and bind the copper pipes , the drain pipe and the power cables together with the tape with the drain pipe at the bottom, so that water can flow freely.
INSTALLATION MANUAL---Installation of the Indoor unit INSTALLATION OF THE INDOOR UNIT After having connected the pipe according to the instructions, install the connection cables. Now install the drain pipe. After connection,lag the pipe, cables and drain pipe with the insulating material. 1. Arrange the pipes ,cables and drain hose well. 2. Lag the pipe joints with insulating material , securing it with vinyl tape. 3.
INSTALLATION MANUAL---Installation of the outdoor unit ELECTRICAL CONNECTIONS wiring diagram on the back of the cover 1. Remove the handle on the right side plate of outdoor unit. 2. Connect the power connection cord to the terminal board. Wiring should fit that of indoor unit. 3. Fix the power connection cord with wire clamp. 4. Confirm if the wire has been fixed properly. 5. An efficient earth connection must be ensured. 6. Recover the handle.
INSTALLATION MANUAL---Installation of the outdoor unit BLEEDING The air and humidity left inside the refrigerant circulation can cause compressor malfunction. After having connected the indoor and outdoor units, bleed the air and humidity from the refrigerant circulation using a vacuum pump. (1) Unscrew and remove the caps from the 2 - way and 3-way valves. (2) Unscrew and remove the cap from the service port. (3) Connect the vacuum pump hose to the service port.
INSTALLATION MANUAL---Information for the installer FIXED-SPEED TYPE 5k 7k 9k 12k 15/18k 1/4 ( 6) 3/8 ( 9.52) 1/4 ( 6) 3/8 ( 9.52) 1/4 ( 6) 3/8 ( 9.
INSTALLATION MANUAL---Information for the installer WIRING DIAGRAM For different models, the wiring diagram may be different. Please refer to the wiring diagrams pasted on the indoor unit and outdoor unit respectively. On indoor unit, the wiring diagram is pasted under the front panel; On outdoor unit, the wiring diagram is pasted on the backside of the outdoor handle cover.
INSTALLATION MANUAL---Information for the installer CABLE WIRES SPECIFICATION 5k MODEL 7k 12k 9k 22/24k 28/30k/36k 15/18k capacity (Btu/h) sectional area 2 2 N 1.0mm AWG18 1.0mm AWG18 1.0mm AWG18 2 1.0mm AWG18 2 L 1.0mm AWG18 1.0mm AWG18 E 1.0mm AWG18 2 1.0mm AWG18 2 1.0mm AWG18 N 1.0mm2 1.0mm2 1.0mm2 L 1.0mm 1.0mm22 (1.5mm) AWG18 (AWG16) 1.5mm AWG16 1.0mm2 (1.5mm)2 AWG18 (AWG16) 1.5mm AWG16 2 Power supply cable 2 2.5mm2 AWG14 H05RN-F 4.0mm AWG12 2.
MAINTENANCE Periodic maintenance is essential for keeping your air conditioner efficient. Before carrying out any maintenance , disconnect the power supply by taking the plug out from the socket. INDOOR UNIT ANTIDUST FILTERS 1. Open the front panel following the direction of the arrow 2. Keeping the front panel raised with one hand, take out the air filter with the other hand 3. Clean the filter with water ; if the filter is soiled with oil,it can be washed with warm water (not exceeding 45 ).
TROUBLESHOOTING MALFUNCTION POSSIBLE CAUSES Power failure/plug pulled out Damaged indoor/outdoor unit fan motor Faulty compressor thermomagnetic circuit breaker The appliance does not Faulty protective device or fuses. operate Loose connections or plug pulled out It sometimes stops operating to protect the appliance.
CONTACT DETAILS Glen Dimplex Australia Pty Ltd 1340 Ferntree Gully Road Scoresby VIC 3179 Australia Ph: 1300 556 816 http://www.tclair.com.au/ Http://www.tclair.com.