Information

・All specifications are subject to change without notice.
17
CC15-E Specifications
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside thi
s temperature range, derating is needed.
(*3) Output voltage includes input change, load change (balanced load), and temperature change.
(*4) In 50MHz, Ta=25°C.
(*5) Latch method Resumes by restarting input or resetting remote on/off.
CC15-E
MODEL
ITEMS/UNITS
CC15-2403Sx-E CC15-2405Sx-E
Input
Nominal Voltage V DC24
Voltage Range V DC18-36
Efficiency (typ) (*1) 89
Current (typ) (*1) A 0.695 0.702
Output
Nominal Voltage
VDC
3.3 5
Maximum Current A 4.500 3.000
Maximum Power (*2) W 14.85 15
Maximum Line Regulation(Within input voltage range)
mV 65 100
Maximum Load Regulation (0-100% load)
mV 120 200
Temperature Coefficient
(Ambient temperature -40 to +50 )
80mV
Max Power Total Regulation (ma
x) (*3) +5/-3
Maximum Ripple & Noise (typ/max) (*4)
mVp-p
40/120
Voltage Adjustable Range Not available
Function
Over Current Protection (*5) Available
Over Voltage Protection Not available
Remote ON/OFF Control Available
Environment
Operating Temperature -40 to +85
Storage Temperature -40 to +85
Operating Humidity
RH
5-95 (the conditions of maximum 38 in wet bulb temperature and non-condensation should be ensured.)
Storage Humidity
RH
5-95 (the conditions of maximum 38 in wet bulb temperature and non-condensation should be ensured.)
Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Isolation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation Resistance
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M min
Standards
Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Mechanical
Weight (typ) g 12.5
Size (W x H x D) mm DIP: 37.55 x 7.0 x 32.1 / SMD: 37.55 x 7.5 x 32.1