Instructions

INSTRUCTION MANUAL
CCG
TDKLambda
<Page>
16/20
0
20
40
60
80
100
120
40 50 60 70 80 90 100
Output current (%)
Ambient temperature (ºC)
85
40
0
20
40
60
80
100
120
40 50 60 70 80 90 100
Output current (%)
Ambient temperature (ºC)
8540
0
20
40
60
80
100
120
40 50 60 70 80 90 100
Output current (%)
Ambient temperature (ºC)
85
40
0
20
40
60
80
100
120
40 50 60 70 80 90 100
Output current (%)
Ambient temperature (ºC)
85
40
72. Output Derating Curve
The following Output Current VS Ambient Temperature is a measurement data when mounting on our
evaluation PCB. The output derating curve is affected by the mounting board, the external components,
and the ambient conditions. Therefore, use it after confirming the case temperature when the power
supply operates with actual device does not exceed 110ºC (Temperature Measurement Point On The
Case). Moreover, use below 85ºC ambient temperature.
Evaluation PCB Specification
Size 150mm×70mm t = 1.6mm
Material FR4 (Double sided
Copper 35μm
(3) Temperature Measurement Point on The Case
Confirm the temperature measurement point on the case of Fig.73 is below 110ºC.
Moreover, clear the hole at the center of the label, and measure the metal part when you measure the
case temperature.
Fig.73 Temperature Measurement Point on The Case
CL
Temperature Measurement Point on The
Case (Center of the case)
CCG302412S CCG302415S
CCG302403S CCG302405S
(1) Output Current VS Ambient Temperature (Reference data : Vin=Typ.)
Natural
Convection
0.5m/s
1.0m/s
Natural
Convection
0.5m/s
1.0m/s
Natural
Convection
0.5m/s
Natural
Convection
0.5m/s
CL