Data Sheet

CCG15-30 Series
,QGXVWULDO 7HVW
15 to 30W
DC-DC Converters
CCG15-30 Series
1
www.emea.tdk-lambda.com/ccg15 30
Features Benets
• Industry Standard 1” x 1” Footprint • Fits in place of 2 x 1” converters
• Wide Range DC Input 9 - 36 or 18 - 76V • Less Parts to Inventory
• High Efciency - Up to 92% • Easier System Thermal Management
• Six Sided Shielding • Reduced Radiated Noise
&RPP
%URDGFDVW
Specication
Model CCG15/CCG30
Nominal Output Voltage VDC 3.3V 5V 12V 15V 24V 30V ±12V ±15V
Input Voltage Range VDC 9 - 36V or 18 - 76VDC
Input Current A See model selector
Output Voltage Adjustment VDC 2.97 - 3.63 4.5 - 5.5 10.8 - 13.2 13.5 - 16.5 None
Output Voltage Accuracy % ±2% ±5%
Ripple & Noise (max) pk-pk mV 70 70 95 95 190 190 95 95
Line Regulation (max) mV 13.2 20 48 60 120 150 60 75
Load Regulation (max) mV 13.2 20 48 60 240 300 120 150
Cross Regulation (1) mV Not applicable 480 600
Overcurrent Protection % >105% (Hiccup current style)
Overvoltage Protection % -
Remote On/Off Standard: Low = ON, Open = OFF. Positive Logic (/P sufx): Open = ON, Low = OFF
Operating Temperature °C -40°C to +110°C Case, -40°C to +85°C Ambient. See installation manual for operation above 60°C
Storage Temperature °C -55°C to +125°C
Temperature Coefcient %/°C 0.02%/°C
Humidity (non condensing) %RH 5 - 95% RH Operating and Non Operating
Cooling - Convection or forced air
Withstand Voltage VAC Input to Case: 1kVDC; Input to Output 1.5kVDC; Output to Case: 1kVDC
Isolation Resistance MΩ >100M at 25°C and 70%RH, Output to Case 500VDC
Vibration -
Non Operating, 10-55Hz (sweep for 3 min.)
Amplitude 1.52mm constant (Max 90.8m/s
2
) X,Y,Z 1 hour each
Shock - 490.3m/s
2
Safety Agency Certications - IEC/EN/UL/CSA60950-1, IEC/EN/UL/CSA62368-1 and CE Mark
Weight (Typ) g 20
Size (WxHxD) mm 25.4 x 9.9 x 25.4
Warranty yrs 5
Note: See Installation Manual for full details, test methods of parameters and application notes (1) Dual outputs only. One output at 100%, the other output at 20% load