User manual

Page 16 of 16 DPP480-xx-1, 23421 issue 03, April 2013
Product HANDBOOK
DPP48
-
xx
-
Mechanical Outline Drawings:
Front panel indicators:
DC ON - The Green LED is on when the output voltage is >75%.
DC LOW - The red LED is on when the output voltage is between 70 – 90%.
The output can be increased by turning the front panel potentiometer clockwise, turning the potentiometer
counter clockwise will decrease the output.
Adjusting output voltage beyond the stated range may cause overvoltage protection (OVP) to clamp the
output. To reset for normal operation simply adjust the potentiometer to reduce the output voltage to within its
range (see table above)
Power ready signal (Rdy) 24V model only.
Contact closed at start up – threshold voltage 17.6 – 19.4Vdc
Contact electrical isolation 500Vdc
Contact rating 60Vdc/0.3A
Weight: DPP480-xx-1 weighs 1920g