1.2.9 Cooling and mechanical construction
1.3.1 General
1.3.2 Serial link cable
1.3.4 AC cables
The Genesys series is cooled by internal fans. At the installation, care must be taken to
allow free air flow into the power supply via the front panel and out of the power supply via
the rear panel. The Genesys power supplies have a compact and lightweight package
which allows easy installation and space saving in the application equipment.
Accessories are delivered with the power supply or separately upon ordering. The list below
shows the possible accessories and ordering numbers.
S
TM
TM
1.3 ACCESSORIES
erial link cable, for linking power supplies by RS485 communication is provided with the
power supply.
Cable description: 0.5m length, shielded, RJ-45 type plugs, 8 contacts (P/N: GEN/RJ45).
* DB25 plug kit (AMP, 749809-9).
* Output terminal shield
AC cables are not provided with the power supply. If an AC cable is required, it should be
ordered according to following:
Part no. Market Description
NC301 USA 13A125V, unshielded, 2m typical length, with IEC320 connector on
one end and NEMA-5-15P connector on the other end.
NC302 Europe 10A 250V, unshielded, 2m typical length, with IEC320 connector
on one end and INT’L 7 standard VII, dual earthing.
NC303 General 10A 250V, unshielded, 2m typical length, with IEC320 connector
on one end and unterminated stripped wires on the other end.
Use the cable only with plug approved by the national safety
standards of the country of usage.
NC305 Japan 13A 125V, unshielded, 2m typical length, with IEC320 connector
on one end and Japan type plug on the other end.
NC306 UK 10A 250V unshielded, 2m typical length, with IEC320 connector
on one end and UK type plug on the other end.
For 1500W Genesys power supplies the recommended AC cable (customer supplied) is:
25A 250V, 3x12AWG, outer diameter: 9-11mm, rated 60 C min.,
3m max. length. Add a non-locking plug approved by the national
safety standards of the country of usage.
Refer to section 7.4
1.3.3 Misc. hardware
1.3.5 Serial Port Cables
TM
O
8
(GEN/U)
(GEN/E)
(GEN/O)
(GEN )/J
(GEN/GB)
Observe all torque guidelines within this manual. Over torqueing may damage
unit or accessories. Such damage is not covered under manufacturers warranty.
CAUTION
CHAPTER 2 SPECIFICATIONS
2.1 OUTPUT RATING
2.2 INPUT CHARACTERISTICS
1.Input voltage/freq.(*3)
2.Input current (at 100/200Vac)
3.Power Factor
4.750W models Efficiency (*4)
5.1500W models Efficiency (*4)
6.Inrush current at 100/200V
---
A
---
%
%
A
85~265Vac continuous , 47~63Hz,single phase.
10.5/5 for 750W models, 21/11 for 1500W models.
0.99@100/200Vac , rated output power.
Less than 25A for 750W models, 50A for 1500W models.
V
6 8 12.5 20 30 40
50
60 80 100 150 300
600
76/78
77/79
77/80
78/81
81/84
82/85
82/85
83/86
82/85
83/86
83/87
84/88
83/87
84/88
-
84/88
83/87
84/88
83/87
84/88
83/87
84/88
83/87
84/88
83/87
84/88
1.Vout voltage programming
2.Iout voltage programming
3.Vout resistor programming
4.Iout resistor programming
5.On/off control
6.Output current monitor
7.Output voltage monitor
8.Power supply OK signal
9.Parallel operation
10.Series operation
11.CV/CC indicator
12.Enable/Disable
13.Local/Remote analog control
14.Local/Remote analog indicator
---
---
---
---
---
---
---
---
---
---
---
---
---
---
0~100%, 0~5V or 0~10V, user select. Accuracy and linearity: +/-0.5% of rated Vout.
0~100%, 0~5V or 0~10V, user select. Accuracy and linearity: +/-1% of rated Iout.
0~100%, 0~5/10Kohm full scale, user select. Accuracy and linearity: +/-1% of rated Vout.
0~100%, 0~5/10Kohm full scale, user select. Accuracy and linearity: +/-1.5% of rated Iout.
By electrical Voltage: 0~0.6V/2~15V or dry contact, user selectable logic.
0~5V or 0~10V, user selectable. Accuracy: 1%.
0~5V or 0~10V, user selectable. Accuracy : 1%.
4~5V-OK, 0V-Fail. 500ohm series resistance.
Possible , up to 4 units in master/slave mode with single wire current balance connection.
Possible (with external diodes), up to 2 units.
CV: TTL high (4~5V), source current: 10mA, CC: TTL low (0~0.6V), sink current: 10mA.
Dry contact. Open: off, Short: on. Max. voltage at Enable/Disable in: 6V.
By electrical signal or Open/Short: 0~0.6V or short: Remote, 4~5V or open: Local.
Open collector. Local: Open, Remote: On. Maximum voltage: 30V, maximum sink current: 5mA.
2.3 CONSTANT VOLTAGE MODE
1.Max. Line regulation (*5)
2.Max Load regulation (*6)
3.Ripple and noise (p-p , 20MHz) (*10)
4.Ripple r.m.s., 5Hz~1MHz (*10)
5.Temperature coefficient
6.Temperature drift
7.Rem. sense compensation/wire
8.Up-prog. response time, 0~Vomax(*9)
9.Down-prog. response time: Full load
No load
10.Transient response time
11.Hold-up time
V
6 8 12.5 20 30 40
50
60 80 100 150 300 600
---
---
mV
mV
---
V
mS
mS
mS
mS
PPM/C
0.01% of rated output voltage +2mV
0.01% of rated output voltage +2mV
60
8
60
8
60
8
60
8
60
8
60
8
60
8
60
8
80
8
80
8
100
10
150
25
300
60
100PPM/ from rated output voltage, following 30 minutes warm-up.
0.05% of rated Vout over 8hrs interval following 30 minutes warm-up. Constant line, load & temp.
O
C
1
1
1
1 1.5 2
2
3 4 5 5 5 5
80
150
10
50 80
150
500
600
700 800 900 1000
1500
2000 2500 4000
More than 20mS, 100Vac, rated output power.
1100
1100
1200
Time for the output voltage to recover within 0.5% of its rated output for a load change 10~90% of rated
output current.
Output set-point: 10~100%.
Less than 1mS, for models up to and including 100V. 2mS, for models above 100V.
250
250
1.Rated output voltage(1*)
2.Rated output current 1500W (*2)
3.Rated output power 1500W
1.Rated output voltage (1*)
2.Rated output current 750W (*2)
3.Rated output power 750W
V
A
W
A
W
6
200
1200
100
600
8
180
1440
90
12.5
120
1500
60
750
20
76
1520
38
760
30
50
1500
25
750
40
38
1520
19
760
50
30
1500
-
-
60
25
1500
12.5
750
80
19
1520
9.5
760
100
15
1500
7.5
750
150
10
1500
5
750
300
5
1500
2.5
750
600
2.6
1560
1.3
780
MODEL
GEN
6-200
8-180
12.5-120
20-76
30-50
40-38
50-30
60-25
80-19
100-15
150-10
300-5
600-2.6
V
6
8
12.5
20
30
40
-
60
80
100
150
300
600
MODEL
GEN
6-100
8-90
12.5-60
20-38
30-25
40-19
-
60-12.5 80-9.5
100-7.5
150-5 300-2.5 600-1.3
2.5 ANALOG PROGRAMMING AND MONITORING
V
6 8 12.5 20 30 40
50
60 80 100 150 300
600
2.4 CONSTANT CURRENT MODE
1.Max. Line regulation (*5)
2.Max. Load regulation (*7)
3.Ripple r.m.s. 5Hz~1MHz: 750W (*8)
1500W (*8)
4.Temperature coefficient
5.Temperature drift
6. Warm up drift
---
---
---
---
mA
mA
PPM/C
0.01% of rated output current +2mA
0.02% of rated output current +5mA
100PPM/ C from rated output current, following 30 minutes warm-up.
0.05% of rated Iout over 8hrs interval following 30 minutes warm-up. Constant line, load & temp.
Less than 0.1% rated output current over 30 minutes following power on or output voltage change or load
current change.
O
200
400
180
360
120
240
76
152
63
125
48
95
38
75
-
85
29
57
23
45
18
35
13
25
8
12
9
720