Instructions
12
2.13 GENESYS 750W & 1500W POWER SUPPLIES
OUTLINE DRAWINGS
TM
482.8+/-1.0mm
43.6+/-0.3mm
24.5
A
A A
595.3+/-1.0mm
497.8+/-1.0mm
57.8+/-0.5
92.0+/-0.5
92.0+/-0.5
21.0
432.8+/-1.0mm
J2
AC INPUT
ON
OFF
OUT
IN
J3
J1
SW1
422.8+/-1.0mm
Note 1
Note 5
Note 2 (80V~600V)
Note 2
NOTES:
1.Mating plug supplied with power supply.
2.Bus-bars for 6V to 60V models. See detail.
Wire clamp connector for 80V to 600V models (shown).
3. AC cable strain relief for 1500W models only (supplied
with power supply).
4. IEC connector for 750W models. Wire clamp terminal for
1500W models (shown).
5. Chassis slides, GENERAL DEVICES P/N: CC3001-00-S160
or equivalent, mounting holes #10-32 marked "A".
6. Bus Bars output connector enclosure for 60V to 600V.
7. Mounting holes for 19” rack. Uae M6x16
screws to fix the unit to the rack.
104+/-2.0mm
Note 4
Note 7
Note 3
Note 6
39.5+0.5mm
22.0mm
3.0mm
30.0mm
Bus-Bar Detail
6V to 60V Models
8.5mm
T
D
L
a
m
b
d
a
-
I
T
D
L
amb
d
a
-
I
0-8V 0-300A
GEN8-300
12