Instructions

22
The 80V to 600V models have a four terminal wire clamp output connector:
Phoenix Contact P/N: FRONT4-H-7.62/4.
The two left terminals are the positive outputs and the other two right terminals are the negative
outputs. Max. 30A per terminal.
The connector requirements are as follows:
1. Wires: AWG18 to AWG10.
2. Tightening torque: 4.4-5.3Lb-inch. (0.5-0.6Nm).
Follow the below instructions for connection of the load wires to the power supply:
1. Strip approx.10mm at the end of each of the load wires.
2. Loosen the connector terminal screws.
3. Loosen screw “B” from enclosure bottom cover to release the shutter.
4. Insert stripped wires into enclosure bottom cover opening and then to the terminals,
tighten the terminals screws securely (see fig.3-8)
5. Loosen the two chassis screws marked “A” halfway.
6. Assemble the enclosure top cover to the chassis and tighten screws “A” (tightening torque:
4.8 - 5.3 Lb-inch).
7. Assemble the enclosure bottom cover to it’s place, as shown in Fig.3-9,using screw “C”,
(tightening torque 4.8-5.3 Lb-inch).
8. Slide down the shutter to secure load wires in place, and tighten screw “B”.
Fig.3-9: Enclosure assembly
B
Fig.3-8: Load wires connection to the output connector
Load wires
Negative (-)
Output/Return
Positive output (+)
Shutter
Enclosure bottom cover
Enclosure top cover
C
B
A
A
22