Data Sheet

Genesys ™ 750W/1500W Specifications
Specifications in Blue are improved
750W 1500W
1.0 MODEL GEN 6-200 8-180
12. 5-120
20-76 30-50 40-38 50-30 60-25 80-19 100 -15 150-10 300-5 600-2.6 X
1. Rated output voltage (*1) V 6 8 12. 5 20 30 40 50 60 80 100 150 300 600 X
2. Rated Output Current (*2) A 200 180 120 76 50 38 30 25 19 15 10 5 2.6 X
3. Rated Output Power W 1200 1440 1500 1520 1500 1520 1500 1500 1520 1500 1500 1500 1560 X
4. Efficiency at 100/200Vac (*3) % 77/79 78/81 82/85 83/86 83/86 84/88 84/88 84/88 84/88 84/88 84/88 84/88 84/88 X
1.0 MODEL GEN 6-100 8-90 12. 5-60 20-38 30-25 40-19 --- 60 -12.5 80-9.5 10 0 -7. 5 150-5 300-2.5 600-1.3 X
1. Rated output voltage (*1) V 6 8 12. 5 20 30 40 --- 60 80 100 150 300 600 X
2. Rated Output Current (*2) A 100 90 60 38 25 19 --- 12. 5 9.5 7. 5 5 2.5 1.3 X
3. Rated Output Power W 600 720 750 760 750 760 --- 750 760 750 750 750 780 X
4. Efficiency at 100/200Vac (*3) % 76/78 77/80 81/84 82/85 82/85 83/87 --- 83/87 83/87 83/87 83/87 83/87 83/87 X
1.1 CONSTANT VOLTAGE MODE
1. Max.line regulation (0.01% of Vo+ 2mV)(*4) mV 2.6 2.8 3.3 4 5 6 7 8 10 12 17 32 62 X X
2. Max load regulation (0.01% of Vo+2mV )(*5) mV 2.6 2.8 3.3 4 5 6 7 8 10 12 17 32 62 X X
3. Ripple and noise p-p 20MHz (*9) mV 60 50 60 60 50 60 40 60 75 75 75 130 300 X X
4. Ripple r.m.s 5Hz~1MHz (*9) mV 8 6 7 7. 5 6 7 5 7 7 8 8 20 60 X X
5. Remote sense compensation/line V 1 1 1 1 1.5 2 2 3 4 5 5 5 5 X X
6. Temp. coefficient PPM/°C 50PPMC of rated output voltage, following 30 minutes warm up X X
7. Temp. stability
%
0.01% of rated Iout
over 8hrs interval following 30 minutes warm-up. Constant line, load & temp. X X
8. Up-prog. response time, 0~Vo Rated
mS
80mS, N.L/F.L, resistive load 150mS, N.L/F.L, resistive load 250 X X
9. Down-prog response time full-load mS 10 50 80 150 250 X X
10. Down-prog response time No-load mS 500 600 700 800 900 1000 110 0 110 0 120 0 1500 2000 2500 4000 X X
11. Transient response time (*8) mS Less than 1mSec for models up to and including 100V. 2mSec for models above 100V
X X
12. Temp. drift % 0.01% of rated Vout over 8hrs interval following 30 minutes warm up. Constant line, load & temp.
X X
1.2 CONSTANT CURRENT MODE
1. Max.line regulation (0.01% of Io+ 2mA)(*4) mA 12 11 8.0 5.8 4.5 3.9 --- 3.25 2.95 2.75 2.5 2.25 2.13 X
2. Max.load regulation (0.02% of Io+5mA)(*6) mA 25 23 17 12.6 10 8.8 --- 7. 5 6.9 6.5 6.0 5.5 5.26 X
3. Ripple r.m.s 5Hz~1MHz . (*7) mA 190 160 110 50 45 30 --- 15 10 10 8 6 4 X
4. Max.line regulation (0.01% of Io+ 2mA)(*4) mA 22 20 14 9.6 7. 0 5.8 5 4.5 3.9 3.5 3.0 2.5 2.26 X
5. Max.load regulation (0.02% of Io+5mA)(*6) mA 45 41 29 20.2 15 12.6 11 10 8.8 8.0 7.0 6.0 5.52 X
6. Ripple r.m.s 5Hz~1MHz .(*7) mA 350 300 210 120 60 65 60 60 40 20 15 15 7 X
7. Temp. coefficient PPM/°C 70PPM/°C from rated output voltage, following 30 minutes warm up
X X
8. Temp. drift % 0.01% of rated Vout over 8hrs interval following 30 minutes warm up. Constant line, load & temp.
X X
9. Warm up drift %
Less than 0.1% rated output current over 30 min following power on or output voltage / current change
X X
1.3 PROTECTIVE FUNCTIONS
1. OCP 0~105% Constant Current X X
2. OCP Foldback Output shut down when power supply change from CV to CC. User selectable. X X
3. OVP type Inverter shut-down, manual reset by AC input recycle or by OUT button or by communication port X X
4. OVP trip point
0.5~7.5V 0.5~10V 1~15V 1~24V 2~36V 2~44V 5~57V 5~66V 5~88V 5~110V 5~165V 5~330V 5~660V
X X
5. Over Temp Protection User selectable, latched or non latched X X
1.4 ANALOG PROGRAMMING AND MONITORING
1. Vout Voltage Programming 0~100%, 0~5V or 0~10V, user select. Accuracy and linearity: +/-0.5% of rated Vout. X X
2. Iout Voltage Programming 0~100%, 0~5V or 0~10V, user select. Accuracy and linearity: +/-1% of rated Iout. X X
3. Vout Resistor Programming 0~100%, 0~5/10Kohm full scale,user select.,Accuracy and linearity: +/-1% of rated Vout. X X
4. Iout Resistor Programming 0~100%, 0~5/10Kohm full scale,user select. Accuracy and linearity: +/-1.5% of rated Iout. X X
5. On/Off control (rear panel) By electrical. Voltage: 0~0.6V/2~15V, or dry contact, user selectable logic X X
6. Output Current monitor 0~5V or 0~10V, accuracy: 1%, user selectable X X
7. Output Voltage monitor 0~5V or 0~10V, accuracy: 1%, user selectable X X
8. Power Supply OK signal TTL high (4~5V) -OK, 0V-Fail 500ohm series resistance X X
9. CV/CC indicator Open collector, CC mode: On, CV mode: Off, Maximum voltage: 30V, maximum sink current: 10mA X X
10. Enable/Disable Dry contact. Open: off, Short: on. Max. voltage at Enable/Disable in: 6V X X
11. Local/Remote analog control By electrical signal or Open/Short: 0~0.6V or short: Remote, 2~15V or open: Local. X X
12. Local/Remote analog control indicator Open collector, Local: Open, Remote: On. Maximum voltage: 30V, maximum sink current: 5mA. X X
1.5 FRONT PANEL
1. Control functions
Vout/Iout manual adjust by separate encoders (coarse and fine adjustment selectable) X X
OVP/UVL manual adjust by Volt. Adjust encoder X X
AC on/off, Output on/off, Re-start modes (auto, safe), Foldback control (CV to CC), Go to local control X X
Address selection by Voltage (or current) adjust encoder. Number of addresses: 31 X X
RS232/485 and IEEE488.2 selection by IEEE enable switch and DIP switch X X
Baudrate selection: 1200, 2400, 4800, 9600 and 19,200 X X
2. Display
Voltage 4 digits, accuracy: 0.05%+/-1 count X X
Current 4 digits, accuracy: 0.2%+/-1 count X X
3. Indications Voltage, Current, Alarm, Fine, Preview, Foldback, Local, Output On, Front Panel Lock X X
1.6 Interface RS-232&RS-485 or Optional GPIB / LAN Interface 750W 1500W
Model V 6 8 12.5 20 30 40 50 60 80 100 150 300 600 X X
1. Remote Voltage Programming (16 bit)
Resolution (0.02% of Vo Rated) mV 0.12 0.16 0.25 0.4 0.6 0.8 1.0 1.2 1.6 2.0 3.0 6.0 12.0 X X
Accuracy 0.05%Vo Rated Output Voltage (*11)
mV 3.0 4.0 6.3 10 15 20 25 30 40 50 75 150 300 X X
2. Remote Current Programming (16 bit)
Resolution (0.002% of Io Rated)
mA 2.00 1.80 1.20 0.76 0.50 0.38 --- 0.25 0.19 0.15 0.10 0.05 0.03 X
Accuracy (0.1% of Io Rated+0.1% of Io Actual Output)
(*10)
mA 200 180 120 76 50 38 --- 25 19 15 10 5.0 2.6 X
Resolution (0.002% of Io Rated)
mA 4.0 3.60 2.40 1.52 1.0 0.76 0.60 0.50 0.38 0.30 0.20 0.10 0.05 X
Accuracy (0.1% of Io Rated+0.1% of Io Actual Output)
(*10)
mA 400 360 240 152 100 76 60 50 38 30 20 10 5.2 X
3. Readback Voltage
Resolution of Vo Rated mV 0.12 0.16 1.125 1.20 1.20 1.2 1.5 1.2 1.60 11. 0 10.50 12 12 X X
Accuracy 0.05% Vo Rated mV 3 4 6.3 10 15 20 25 30 40 50 75 150 300 X X
4. Readback Current
Resolution of Io Rated
mA 11 1.80 1.20 1.14 1.25 1.14 --- 1.13 0.19 0.15 0.15 0.13 0.12 X
Accuracy 0.3% of Io Rated (*10)
mA 300 270 180 114 75 57 --- 37. 50 28.50 22.50 15 7. 50 3.90 X
Resolution of Io Rated output
mA 12 10.80 10.80 1.52 1.50 1.14 1.20 1.25 1.14 1.05 1.10 0.15 0.10 X
Accuracy 0.3% of Io Rated (*10)
mA 600 540 360 228 150 114 90 75 57 45 30 15 7. 8 X
5. OVP/UVL Programming
Resolution (0.1% of Vo Rated) mV 6 8 12 20 30 40 50 60 80 100 150 300 600 X X
Accuracy (1% of Vo Rated) mV 60 80 125 200 300 400 500 600 800 1000 1500 3000 6000 X X
*1: Minimum voltage is guaranteed to maximum 0.2% of Vo Rated.
*2: Minimum current is guaranteed to maximum 0.4% of Io Rated.
*3: At maximum output power.
*4: 85~132Vac or 170~265Vac, constant load.
*5: From No-load to Full-load, constant input voltage.
*6: For load voltage change, equal to the unit voltage rating, constant input voltage.
*7: For 6V models the ripple is measured at 2~6V output voltage and full output current. For other
models, the ripple is measured at 10~100% output voltage and full output current.
*8: Time for the output voltage to recover within 0.5% of its rated for a load change 10~90% of rated
output , Output set-point:10~100%.
*9: For 6V~300V models: measured with JEITA RC-9131A 1:1 probe. For 600V model: measured with
10:1 probe Accuracy -Values have been calculated at Vo Rated & Io Rated.
*10: The Constant Current programming readback and monitoring accuracy does not include the
warm-up and Load regulation thermal drift.
*11: Measured at the sense point.
7.Temp. stability
%
0.01% of rated Vout
over 8hrs interval following 30 minutes warm-up. Constant line, load & temp.
4 | GENESYS| 750-1500kW