Instructions

CHAPTER 2 SPECIFICATIONS
1.Vout voltage programming
2.Iout voltage programming (*13)
3.Vout resistor programming
4.Iout resistor programming (*13
5.On/off control
6.Output current monitor (*13)
7.Output voltage monitor
8.Power supply OK signal
9.Parallel operation
10.Series operation
11.CV/CC indicator
12.Enable/Disable
13.Local/Remote analog control
14.Local/Remote analog indicator
)
2.5 ANALOG PROGRAMMING AND MONITORING
---
---
---
---
---
---
---
---
---
---
---
---
---
---
0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-0.5% of rated Vout.
0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-1% of rated Iout.
0~100%, 0~5/10Kohm full scale, user selectable. Accuracy and linearity: +/-1% of rated Vout.
0~100%, 0~5/10Kohm full scale, user selectable. Accuracy and linearity: +/-1.5% of rated Iout.
By electrical Voltage: 0~0.6V/2~15V or dry contact, user selectable logic.
0~5V or 0~10V, user selectable. Accuracy: +/-1%.
0~5V or 0~10V, user selectable. Accuracy : +/-1%.
4~5V-OK, 0V-Fail. 500ohm series resistance.
Possible , up to 4 units in master/slave mode with two wires current balance connection.
Possible (with external diodes), up to 2 units.
Open collector. CC mode: On, CV mode: Off. Maximum voltage: 30V, maximum sink current: 10mA.
Dry contact. Open: Off, Short: On. Max. voltage at Enable/Disable in: 6V.
By electrical signal or Open/Short: 0~0.6V or short: Remote, 2~15V or open: Local.
Open collector. Local: Open, Remote: On. Maximum voltage: 30V, maximum sink current: 10mA.
2.1 OUTPUT RATING
1.Rated output voltage(1*)
2.Rated output current (*2)
3.Rated output power
V
A
W
MODEL
GEN
8-400
8
400
3200
10-330
10
330
3300
15-220
15
220
3300
20-165
20
165
3300
30-110
30
110
3300
40-85
40
85
3400
60-55
60
55
3300
80-42
80
42
3360
100-33
100
33
3300
150-22
150
22
3300
200-16.5
200
16.5
3300
300-11
300
11
3300
600-5.5
600
5.5
3300
9
2.2 INPUT CHARACTERISTICS
Single Phase models:
3-Phase, 200V models:
3-Phase, 400V models:
---
---
%
Single Phase models: 170~265V, 47~63Hz
Single Phase models: 0.99@200Vac, rated output power. 3-Phase models: 0.95@200/380Vac, rated output power.
3-Phase, 200V models: 170~265Vac, 47~63Hz
3-Phase, 400V models: 342~460Vac, 47~63Hz
Single-Phase and 3-Phase 200V models: Less than 50A
3-Phase 400V models: Less than 20A
V
8
10
15
20
30
60
40 150
100
80
600
200
300
24.0
14.5
7.2
24.0
14.5
7.2
24.0
14.5
7.2
24.0
14.5
7.2
23.0
14.0
7.0
24.0
14.5
7.2
23.0
13.6
6.8
23.5
14.0
7.0
23.0
13.7
6.8
23.0
13.7
6.8
23.0
13.7
6.8
23.0
13.9
7.0
23.0
13.8
6.9
3.Power Factor (Typ)
4.Efficiency (*4)
5.Inrush current (*5)
2.Maximum
Input current
at 100% load
1.Input voltage/freg. (*3)
---
A
82
83
83
83
86
86
87
88
88
88
87
87
87
8
10
15
30
20
40
60
80
150
100
200
300
600
2.3 CONSTANT VOLTAGE MODE
1.Max. Line regulation (*6)
2.Max. Load regulation (*7)
3.Ripple and noise (p-p , 20MHz) (*8)
4.Ripple r.m.s., 5Hz~1MHz
5.Temperature coefficient
6.Temperature stability
7.Warm-up drift
8.Remote sense compensation/wire
9.
11.Transient response time
12.Hold-up time (Typ)
Up-prog. response time, 0~Vomax.(*9)
10.Down-prog. response time
Full load(*9)
No load(*10)
V
---
---
mV
mV
---
---
V
mS
PPM/ C
o
mS
mS
mS
0.01% of rated output voltage +2mV
0.015% of rated output voltage +5mV
55
8
55
7
55
8
55
7
55
7
70
20
100
20
350
80
55
7
60
7
100
25
275
70
300
80
50PPM/ C from rated output voltage, following 30 minutes warm-up.
O
0.01% of rated Vout over 8 hrs interval following 30 minutes warm-up. Constant line, load & temp.
Less than 0.05% of rated output voltage +2mV over 30 minutes following power on.
2
2
2
2
5
5
5
5
5
5
5
5
200
5
80
250
20
100
500
600
700
800
160
900
1000
300
150
1100
1200
1500
2000
500
3000
3500
4000
Time for output voltage to recover within 0.5% of its rated output for a load change 10~90% of rated output
current. Output set-point: 10~100%, Local sense.
Less than 1mS, for models up to and including 100V. 2mS, for models above 100V.
10mSec for Single-Phase and 3-Phase 200V models, 6mSec for 3-Phase 400V models. Rated output power.
V
8
10
15
20
40
30
60
80
100
150
200
600
300
2.4 CONSTANT CURRENT MODE
1.Max. Line regulation (*6)
2.Max. Load regulation (*11)
3.Load regulation thermal drift
4.Ripple r.m.s. 5Hz~1MHz (*12)
5.Temperature coefficient
6.Temperature stability
7.Warm-up drift
---
---
---
---
---
mA
PPM/ C
o
0.01% of rated output current +2mA
0.02% of rated output current +5mA
70PPM/ C from rated output current, following 30 minutes warm-up.
0.01% of rated Iout over 8hrs interval following 30 minutes warm-up. Constant line, load & temperature.
O
Less than 0.1% of rated output current over 30 minutes following load change.
650
400
300
1000
150
250
20
50
70
60
30
15
8
8~20V model: Less than +/-0.5% of rated output current over 30 minutes following power on.
30V~600V model: Less than +/-0.25% of rated output current over 30 minutes following power on.
9